Why is there blowing from the ventilation? Schemes for arranging ventilation systems in an apartment building Overlapping natural ventilation with a hood

Natural ventilation channels

For effective ventilation, Each room of the house must have two ventilation devices: one is for air supply, the other is for removing air from the room.

Every room in a house or apartment equipped with a supply and exhaust natural ventilation device according to one of three options:

  1. Supply valve in the window or external wall for air flow. Transfer hole into an adjacent room with an exhaust duct for air removal (hole in the door or internal wall, partition).
  2. For air flow - overflow hole from an adjacent room with an inlet valve, and exhaust duct
  3. Inlet valve for inflow, And exhaust duct ventilation to remove air.

Check in the house or apartment where you currently live whether all rooms have air supply and exhaust devices ventilation?!

In which rooms should exhaust ventilation ducts be installed?

Exhaust ducts for natural ventilation must be provided from the following premises Houses:

  • Sanitary facilities - bathroom, toilet, laundry room.
  • Kitchens.
  • Dressing room, storage room - if the doors of the premises open into the living room. If the doors open onto a corridor (hall, kitchen), then you can do one of two things: arrange an exhaust duct from the premises or install a supply valve in a wall or window.
  • The boiler room must have both a ventilation duct and a supply valve.
  • From rooms separated from rooms with a ventilation duct by more than two doors.
  • On the floor above the first, if there are entrance doors from the stairs to the floor, ventilation ducts are made from the rooms indicated above, and/or from the corridor, hall.
  • On the floor above the first, in the absence of entrance doors from the stairs to the floor, a ventilation duct and a supply valve are installed in each room of the floor.

In other rooms of the house that do not have natural ventilation exhaust ducts, be sure to install a supply valve in a window or wall and a flow hole into the adjacent room.

In addition, natural ventilation exhaust ducts are used for ventilation:

  • Sewer pipe riser.

Construction rules (clause 6.5.8 SP 60.13330.2016) require in residential buildings for premises in which gas equipment (gas boilers, water heaters, stoves, etc.), provide mechanical forced exhaust ventilation and natural or mechanical forced ventilation.

Location and dimensions of ventilation ducts

The minimum side size of the natural ventilation channel is 10 cm., and the minimum cross-sectional area is 0.016 m 2., which approximately corresponds to the diameter of a standard ventilation duct pipe - 150 mm.

Channel minimum size will provide air exhaust in a volume of 30 m 3 /hour at length vertical pipe more than 3 m. To increase the performance of the hood, the cross-sectional area of ​​the channel or the length of the channel is increased. Channels less than 2 long m. do not provide the necessary intensity of natural ventilation.

In practice, the length of the ventilation duct on a floor is usually determined by design considerations - the number and height of the upper floors located above, the height of the attic, the length of the pipe above the roof. On the floor, the length of all channels must be the same. This is done so that the traction force in each channel on the floor is approximately the same.

The cross-sectional dimensions of the channels on the floor are often made the same, but for design reasons - it’s more convenient. The performance of the ventilation channel in a particular room on the floor is adjusted by choosing the size of the ventilation grille.

Ventilation ducts from the premises of the house on different floors are placed side by side, combining them into a block of ventilation ducts.

For design reasons, they try to lay several ventilation ducts from rooms on the same floor side by side, in one place - to create a block of ventilation ducts.

Ventilation channel block in stone houses usually placed inside the carrier interior wall at home or attached to the wall.

The block is laid out from masonry materials, for example, brick. In brickwork, it is convenient to make channels with a cross-section that is a multiple of the size of the brick, taking into account the thickness of the joints - 140x140 mm. (1/2 x 1/2 brick, 196 cm 2) or 140x270 mm. (1/2 x 1 brick, 378 cm 2)

Double-channel expanded clay concrete ventilation block 390x190x188 mm. Flow area of ​​one channel 168 cm 2
Concrete blocks for laying ventilation ducts in a private house. Block height 33 cm., width 25 cm., wall thickness 4 cm. The flow area of ​​one channel is 12x17 cm. (204 cm 2)

They produce hollow ones concrete blocks, specially designed for laying ventilation ducts.

A block of ventilation ducts made of masonry materials must be supported on a foundation or on a reinforced concrete floor.

In other cases, for example, in wooden or frame houses, the ventilation channel block is assembled from plastic or galvanized steel pipes. The block of pipes is covered with a box.

How to combine several channels into one channel

In a private house, the number of channels is small, so there is no need to combine air flows from several channels (rooms or floors) into one, as is often done in apartment buildings. Each natural ventilation channel in a private house should begin in the room and end at the head on the roof. Any combination of two or more channels impairs ventilation performance.

In some cases, there is still a need to combine several channels, to combine them into one common natural ventilation channel.


Read:

Ventilation channel performance

Single channel performance exhaust ventilation section 12x17 cm.(204 cm 2) from concrete blocks depending on the channel height and room temperature:


Capacity of natural ventilation channels with a cross section of 12 x 17 cm.(204 cm 2) depending on the channel height and room temperature (at an outside air temperature of 12 o C)

To determine performance for intermediate channel heights, plot the channel height versus performance graph.

Similar tables can be found for ventilation ducts that are made of other materials.

However, for ventilation ducts of the same cross-section (204 cm 2), but made from other materials, the performance will differ slightly from that indicated in the table.

For a channel of a different cross-section, the performance value from the table can be proportionally increased or decreased.

To increase the performance of a ventilation channel of the same height, it is necessary proportionally increase the cross-sectional area of ​​the channel. For this, for example, choose a concrete block with a hole bigger size, or use two or three channels of the above size to ventilate one room.

Calculation of natural ventilation of a private house

IN building regulations the minimum required capacity of natural ventilation channels is indicated. People usually feel better when more water is supplied to the room. fresh air than specified in the standards. The performance of the natural ventilation channel very much depends on atmospheric and other variable factors (air temperature inside and outside, wind pressure and direction, resistance to air flow into the room). All this suggests that for a private house there is no point in carefully performing calculations accurately. I recommend rounding the calculation results towards greater productivity of natural ventilation channels. During operation, if necessary, the channel capacity can be easily reduced.

Calculation of natural ventilation is carried out in order to determine the size of ventilation channels based on the volume of air removed.

When determining the volume of air removed through natural ventilation channels, it is taken into account that rooms with supply valves air comes from the street, then this air flows into rooms with exhaust ducts, and is removed through the ducts again to the street.

Calculation is being carried out for each floor at home in the following order:

  1. Guided by the standards (see), determine the amount of the minimum volume of air that should come from the street for ventilation all rooms with supply valves - Q p, m 3 /hour.
  2. According to the standards, the amount of the minimum volume of air that must be go outside for ventilation all premises equipped with an exhaust ventilation duct - Q in, m 3 /hour.
  3. Compare the calculated minimum values ​​of air flow from the street (Q p, m 3 /hour) and going outside (Q in, m 3 /hour). Usually one of the quantities turns out to be greater than the other. The larger of the two quantities is taken as the minimum design capacity of all exhaust ventilation channels on the floor— Q r, m 3 /hour.
  4. Based on the vertical dimensions of the house, the height of the natural ventilation channel on the floor is determined.
  5. Knowing the height of the ventilation channel, and the overall estimated minimum performance of all channels on the floor (Q p, m 3 / hour), according to the table (see above) they select total standard channels made of concrete blocks. The total performance of the selected number of standard channels must be no less than the value of Q p, m 3 / hour.
  6. The selected number of standard ducts are distributed between the rooms of the house, which must be equipped with exhaust ventilation ducts. When distributing, take into account the need to ensure standard air exchange in each individual room with a ventilation duct.

An example of calculating the natural ventilation of a private house

For example, let’s calculate natural ventilation in one-story house with a total floor area of ​​120 m 2. There are five in the house living rooms total area 90 m 2, kitchen, bathroom and toilet, as well as a dressing room (storage room) with an area of ​​4.5 m 2. Room height - 3 m. The house is made with natural ventilation of the underground space through ventilation duct. Height of ventilated space under the floor 0.3 m. We use concrete blocks to install ventilation channels - see above.

Fan at the entrance to the natural ventilation channel

Continuation: for the next one

Among those families who live in standard city apartments, there are probably no ones who would not want to increase usable area premises, especially for the traditionally cramped and irrationally planned kitchen space.

Today, there are many ways to solve the problem of cramped space - from expanding the kitchen at the expense of adjacent rooms: a corridor, a storage room, to combining the kitchen and adjacent room into a living room. Much less common are remodeling the kitchen or adding a kitchen, balcony or loggia to the premises.

All these types of redevelopment can be carried out only after appropriate approval of changes , which guarantees the safety of living in your apartment and in the apartments of your neighbors. But some apartment owners increase the kitchen area by remodeling and dismantling the ventilation duct, which is strictly prohibited by current building codes.

Advantages of removing the ventilation duct and ventilation duct:

Of course, partial or complete dismantling of the ventilation duct can provide certain advantages, because in addition to the fact that in the resulting niche in the wall you can put a refrigerator, a small cabinet, install shelves, the empty space resulting after remodeling the ventilation duct can become part of the interior, and the kitchen area will gain some zest.

But practice shows that ventilation redevelopment box and with all its advantages, it has unpleasant consequences that outweigh all the benefits. If you are planning to dismantle the ventilation duct, then you should know that the Housing Inspectorate will not approve such actions. Dismantling the ventilation riser deprives your neighbors of air flow, and the ventilation duct is part of the common property, and turning a blind eye to this when living in apartment building will not work.

Redevelopment of the ventilation duct. P Why can’t it be arranged?

Some ventilation systems are built using self-supporting blocks. Simply put, a ventilation shaft consists of many sections stacked on top of each other. It’s easy to imagine what could happen if you “pull out” such a block, say, on the fifth floor - the entire shaft from the sixth and above will be deprived of support and hang on the walls, and apartments below the fifth will be left without fresh air.

It would seem logical to bypass this ban on the ground floor, because there are no neighbors below, and the box can be fixed right under the ceiling, but this is also prohibited, since the ventilation shaft is common property and not part of your apartment. For the same reason, it is strictly forbidden to interfere with the layout of the ventilation system enclosures.

Ventilation duct in an apartment building, photo:

Sometimes would-be builders remove not the entire box in the kitchen, but part of it, hoping that it will continue to function as before. It’s worth saying right away that even if the size of the ventilation duct makes you think about reducing its area, partial dismantling is also a violation, and is explained by its design. It consists of one large (common) channel and two smaller supply channels.

Photo of the redevelopment of the ventilation duct in the kitchen with violations:

Through small channels, the air rises to a height of three meters from the level of air entry into the exhaust windows, which are usually located in the corner of the kitchen and toilet, and only then enters the common channel. By reducing the cross-section in the exhaust shaft, you create an area high blood pressure, which will not allow air to pass from the lower apartments above. The neighbors below will be very grateful for the collective smell from the entire entrance to their home, because “the exhaust air will go directly to them.

If you are just planning to buy an apartment, then when choosing suitable housing you should pay attention to the presence of illegal redevelopment, and especially ventilation redevelopment, since you will not be able to approve such work in the future “retroactively”, and you will have to eliminate everything at your own expense without permission changes made.

  • It is quite simple to identify illegally carried out redevelopment during an inspection - all unauthorized changes are marked with red lines on the BTI floor plan.
  • The same scheme applies if the ventilation duct in the kitchen is redesignedyou did it yourself.

Technical passport of the apartment with marked illegal alterations:

Fines and penalties for remodeling a ventilation duct or ventilation duct

Once it becomes known about the unauthorized redevelopment (and sooner or later this will happen), you will be required to pay an administrative fine in the amount of 2,500 rubles, and then you will have to, either at your own expense, eliminate all the consequences of the illegal redevelopment and begin restoring the damaged common property.

In general, an apartment with an illegal redevelopment is deprived of many advantages compared to an apartment without redevelopment or housing where the redevelopment was legalized in a timely manner. For example, such an apartment cannot participate in real estate transactions because it is not legally “clean”. In many situations, in order to eliminate this drawback, it is necessary to legalize the redevelopment retroactively.

Ventilation duct inspection report, photo:

Therefore, avoid any work that may affect the ventilation system. However, it is worth noting that in some typical ventilation located in non-obvious places (for example, in load-bearing walls in or). And it is not possible to create openings in these walls to combine rooms.

In old buildings, the location of various ventilation shafts can be completely unexpected. They may be inside brick walls, and this fact sometimes becomes an unpleasant surprise when openings are made without permission. Such openings definitely cannot be saved: they will have to be sealed with the restoration of ventilation.

Dismantling an unused ventilation duct in an old house, photo:

Redevelopment of a ventilation duct in an old house. Dismantling unused ventilation ducts

However, older homes often have chimneys or inoperative ventilation ducts. In principle, it is possible to touch them, but only with the consent of 73% of the residents, since this is common property.

This applies to such changes in the layout of the apartment as, for example, moving or expanding a doorway in a partition, installing or dismantling a partition, remodeling with the organization of a dressing room - most of such work can be agreed upon after it has been carried out. But despite the fact that the Housing Inspectorate often accommodates those who have carried out unauthorized redevelopment in their apartment and often formalizes work already completed,all this does not apply to the illegal redevelopment of the ventilation duct in the toilet, kitchen or other places.

The list of redevelopments, which also cannot be agreed upon after they have been carried out, includes work that violates the stability of the building’s structures, for example, redevelopments affecting the load-bearing walls of the house. Changes in the layout that obviously worsen the living conditions in your apartment are also considered prohibited and you will not be able to approve them “retrospectively”.

You should not carry out work without permission if this makes it difficult to access existing risers - the housing inspection will oblige you to return everything to its previous state before redevelopment is carried out.

Thus, when deciding to remodel your kitchen, if you want to increase the usable area of ​​the kitchen, then you should first of all take care of the legality of your future transformations. To ensure that changes in the layout comply with current building and sanitary standards and do not violate the law, before starting work, you should develop a project for the upcoming redevelopment in an organization with SRO approval, and then obtain written permission to redevelop the premises.

An example of the arrangement of ventilation ducts in non-residential premises, photo:

Examples of failures when coordinating the dismantling of ventilation ducts:

So, let's summarize all of the above:

Dismantle the ventilation duct or ventilation duct in an apartment building, and especially multi-storey building it is forbidden for several reasons:

  • The house ventilation duct only works when assembled, and by reducing its volume you will worsen the living conditions of your neighbors in order to increase free space in the kitchen
  • The ventilation duct is a common property and cannot be dismantled without the consent of your neighbors in the apartment building.
  • Restoring the dismantled ventilation duct will fall on your shoulders, even if you did not produce it but received it “by inheritance”
  • The cost of a mistake is quite high, and when remodeling a kitchen with dismantling the ventilation duct, you will have to restore the duct itself, the ventilation duct, and also pay a fine.
  • As a rule, it is possible to increase the usable area of ​​the kitchen without resorting to such radical measures - it is enough to competently develop a project for changing the configuration of the apartment.
  • In a private house, unlike a multi-storey one, redevelopment of the ventilation duct for exhaust hood is much simpler.
  • Remodeling the kitchen with the dismantling of the ventilation duct is, in principle, inconsistent in the conditions of an apartment building.
  • Such redevelopments are quite easily detected during inspections, for example, during an inspection by a Housing Inspectorate inspector.

Our company will help both with the development of the project and with its approval. Thanks to the experience and everyone necessary tolerances, we guarantee the full legality of the proposed changes.

Unfortunately, the ventilation system sometimes does not work correctly. This is when the ventilation starts to blow back into the living areas of the house. It brings with it air from the ventilation shaft unpleasant aromas, and you can feel it right away. You should not put off solving this problem for a long time, because it will not be solved by itself. Let's figure out why ventilation works in the opposite direction.

Natural ventilation at home

What is this ventilation system? Essentially, this is a complex of air ducts in a private house or a system of shafts in an apartment building, in which there is one main riser stretching from the basement to the roof. It is this that creates the draft due to the temperature difference between indoors and outdoors. And the greater this difference, the stronger the hood works. Let's add wind perpendicular pressure like cross sections. This is when the wind blows in a horizontal direction relative to the riser, and it pulls air from the ventilation with it. That is, air is sucked out of the premises naturally, and not with the help of additional equipment such as a fan.

Of course, in such a system there must be an air flow so that a vacuum does not form inside the house or the draft does not decrease. Therefore, vents are left in the foundation or holes are made in the floor of the first floor.

Causes of air circulation problems

If the ventilation system is not working correctly, there is a reason for it. There are many of them, but the main two are:

  1. There is no supply ventilation.
  2. The temperature inside is lower than outside. This usually happens in the summer when it is hot.

But the main reason is the lack of supply air flows. Usually in apartments the conclusions are in ventilation shaft produced through the bathroom, toilet and kitchen. And the air flow occurred through the windows (their leaks) and front door. Today, when instead wooden windows plastic ones are installed with complete sealing of joints and connections, the inflow problem has become serious. More often reverse thrust appears because of this. This problem is solved by installing supply valves into window systems.

Other causes of traction failure and reverse flow include:

  • malfunctions of the system itself;
  • installing fans instead of grilles;
  • installation flow hood, which is connected to the ventilation duct;
  • absence of an umbrella on the roof or destruction of the mouth of the canal.

Causes of ventilation malfunction

The causes of the malfunction include a large number of factors. The main thing you need to understand is that when there is blowing from the ventilation system in an apartment, it is not the same thing if the same effect appears in a private house. That is, faults in two buildings may be different, because the traction failure in them has different causes.

For example, in an apartment this most often happens due to the installation of a fan or hood in the kitchen, which begins to press through its channel, and the air inside, moving to the riser with pressure, does not have time to pass the entire mass upward. That is, part of it ends up in the adjacent channel of the toilet or bathroom. It is in these rooms that the opposite effect occurs. The same thing happens in the opposite direction, if the fan in the kitchen is turned off and the fan in the toilet is on. This also happens with neighboring apartments located one above the other.

This suggests that you cannot thoughtlessly install additional exhaust devices without calculating their power. And the more powerful the fan, the stronger the reverse draft of the ventilation system in the apartment of a multi-story building.

For this reason, this cannot happen in a private house, because at the design stage today they try to distribute ventilation ducts to all rooms separately. That is, the kitchen has its own riser, and the toilet and bathroom have their own. But sometimes another problem arises in the house. Most often, risers are combined into one or two common channels inside the attic, and then one or two pipes are discharged through roof covering. And here horizontal sections appear in the ventilation system. the main task The designer is to use as little of this type of air duct as possible, and to minimize the angle of inclination of horizontal sections (the reduction should be minimal). That is, the steeper this section, the better the upward air movement.

And three more reasons:

  1. Lack of thermal insulation. Cold air in winter it penetrates into the air ducts, where it freezes, turning into ice. This usually occurs at the mouth of the canal. The consequences are a reduction in the cross section.
  2. Lack of an umbrella (visor), which can lead to rain and reduced traction. This disrupts air exchange.
  3. The ventilation in the house is clogged with debris.

So, in order to remove backdraft, you must first understand why it appears.

Causes of reverse thrust

As mentioned above, reverse draft in ventilation appears for two main reasons:

  1. Complete sealing of the premises.
  2. Installation of additional exhaust devices in ventilation ducts.

All other reasons are secondary, some of which do not create reverse draft, but simply the ventilation stops working. Ventilation in an apartment is more difficult, because the system itself is a complex set of channels, often made of concrete. Branches extend from the riser throughout all apartments, through which air from the premises must be removed to the street. And if a neighbor on the ground floor installs a powerful kitchen hood, then reverse flow air masses will be felt not only by him, but also by neighbors on the floors closest to him.

In a private house, reverse draft occurs for other reasons, because the ventilation in the apartment is different from ventilation system private house. This is where installing fans can solve the problem. But you just need to determine the installation location using different risers.

Self-determination of cravings

  • There are two ways:
  1. The simplest one is to place your palm with ventilation hole, and in case of proper ventilation, you should feel the movement of air flow.
  2. Place a napkin or paper sheet on the grill. If the first holds on to the second, it means the traction is good, there is no reverse effect.

Ventilation problems in multi-apartment buildings

Ventilation problems usually occur after many years of using a home.

  1. Its cross-section becomes smaller due to debris, rodents and birds that have fallen inside.
  2. Destruction of the walls of ventilation ducts due to condensation.
  3. The absence of a head is due to precipitation trapped inside.

All this reduces cravings, which means that the humidity inside the apartments increases, and unpleasant odors will become eternal companions of the rooms. What to do?

Solving the problem using a fan

Many people probably thought that the conversation was about installing fans in place of ventilation grilles. Nobody forbids doing this, although it has already been described above what this can lead to.

We are talking about a fan that is installed in the system on the roof. This may be a mechanical deflector or a rotary turbine. Both devices are powered by the wind, so they are of no use in calm weather. Although, as practice shows, it is the installation of these devices that sharply increases traction and prevents reverse flow.

Regarding the fans ventilation grilles, then you should first calculate their power. It depends on the cross-section of the ventilation ducts and on such indicators as air exchange in the premises. For example, in the kitchen this figure should vary in the range of 12-20 m³/hour depending on the type of stove and the number of burners.

To do this, you need to calculate the volume of the kitchen. For example, a room area of ​​3x4 m with a ceiling height of 3 m, the volume will be 36 m³. Now we multiply the resulting value by a factor of 12-20. At the minimum value, the fan performance is 432, at the maximum 720 m³/hour.

Preventive measures

What needs to be done to prevent backdraft from forming.

  1. Keep the ventilation system in good condition.
  2. Do not install fans or hoods into ventilation ducts. Use a recirculating hood or vent it outside the room to the street: through a wall or window glass.
  3. Install baffles or rotary turbines at the end of the riser.
  4. Organize air flow into the premises by any means.
  5. Install interior doors, which will block the movement of air between rooms. Strong drafts are also causes of backflow.
  6. Clean the ventilation system from snow and ice in winter.
  7. Make periodic

2. Ventilation pipe

It is necessary to look for the marking d125. Some people believe that if you put a 125 pipe into a 132mm hole, there will be a large gap. This is wrong. The diameter of the ventilation pipe is indicated as internal. The wall thickness is about 1.5mm, there will be a slight gap, about 2mm on each side. It will be closed with an outer grille.

  • 3. External grille

    We recommend installing a metal one. As you may have guessed, all elements have a diameter of d125. If you want to install a plastic one, then look for one made of weather-resistant plastic, otherwise, under the influence of sunlight, it will quickly deteriorate: in just a few months it will lose its rigidity and break at the slightest touch.

    Metal RUR 350, weatherproof plastic RUR 150

    • 4. Check valve

      It is necessary to protect the ventilation duct during gusts of wind. Place it closer to the street side, with its axis horizontal.

      You will need to cut the ventilation pipe (), insert a check valve, then.

      1 valve - 90 rub.

    • 5. Exhaust fan

      We recommend Silent 200 CZ. It has a long service life, its plastic is safe for health, has a reliable wire connection, and high performance corresponds to real life. Another important plus is that it is quiet. For the fan test, watch the video below.

      Among the disadvantages, we can note the high cost, BUT, having saved 500 rubles, you can buy a fan whose performance does not correspond to the declared one! It is better to install a high-quality and reliable fan that will work for many years.

      The outer diameter of the fan flange is 120mm. We wrap it (25 rubles) several times so that it fits tightly.

      What's the disadvantage?

      The fan must not be turned off winter period. It must work 24 hours/7, otherwise, when turned off, both the fan and the ventilation duct will freeze. To prevent the channel from freezing, you need to install 3 valves. It works like a vestibule at the entrance. System of 3 check valves creates 3 buffer zones for air, and the temperature difference becomes smoother. You can install 2 valves, but in practice only 3 valves completely eliminate the possibility of freezing. Silent 200 will not be able to push the air flow through 3 valves; a high-pressure fan is required, which is more expensive.

      3 valve design

      The Vort Quadro Micro 80 fan creates the necessary high-pressure pressure of 265Pa (even more than the Micro 100 model), so the air flow is pushed through 3 valves. For comparison, Silent 200 is 82Pa, fans for 1000 rubles in household goods are approximately 25Pa. The valves should be placed as close to each other as possible, but so that they do not interfere with opening.

      What's the disadvantage?

      High cost of the fan

      How to connect a kitchen hood?

      Option No. 1

      If the hole made is the only exhaust ventilation duct, then it is better not to attach a kitchen hood to it, but leave it to remove air with a fan.

      The purpose of the hood is to get rid of fat and unpleasant odors in the air. Polluted air can either be removed from the room or purified. Modern hoods have filters that do a good job of cleaning the air: grease filters that effectively remove grease, and carbon filters that remove unpleasant odors. Therefore, now hoods have a recirculation mode, when the air is not discharged into the ventilation duct, but purified back into the room. There is a disadvantage of the recirculation mode: you need to change the carbon filter every six months, they cost about 1000 rubles.

      Option No. 2

      Extend the air duct.

      Kitchen hoods cannot be kept on always, so a system of 3 valves is needed to protect against freezing when turned off. The hoods are easy to open and have a powerful centrifugal fan inside. You need to connect the channel with plastic ventilation pipes d125. You can reduce noise when working in an air duct by wrapping it in (575r). Unlike isolon, it has an adhesive surface.

      Hole in the wall yourself

      It's quite difficult to do, but possible. To do this you need a hammer drill, a few days of free time and the hands of a hero. In fact, this is not an easy task, if you have never made such a hole, it is better not to start drilling load-bearing wall at home. Unlike diamond drilling when working with a hammer drill:

      1. a lot of dust will be generated that will cover the entire room.
      2. the hole will not be even, so you will have to spread it cement mortar and cover up the voids.
      3. a funnel is formed at the exit photo No. 1
      4. you can burn the hammer drill

      Finding drillers with diamond drilling equipment is not difficult, look on Avito in your city.

      Average price 3000 rub.

      If you want drilling work to take place in the kitchen without dust and dirt, order drillers who deal with home ventilation. Ventilator database. As a rule, on Avito there are builders who are used to drilling in houses under construction, ventilation workers - in apartments with ready renovation, so they have optional equipment for collecting dust and dirt when drilling walls.

      The average price of drilling without dust and dirt is 4000 rubles

      By the way, before you start drilling a wall, ask: “What angle will the hole be at?” The angle must be 0 degrees for the valves to close completely, otherwise they will hang in the air slightly open.

      How much does it cost to make an exhaust hood through the wall to the street, summary.

      If you want something cheaper, with a fan that won’t turn off, then materials + drilling a hole without dust and dirt will cost about 8,500 rubles, based on average prices in Central Russia. Taking into account the fact that you will install it yourself and go shopping in search of the necessary components. Large chain of stores ventilation equipment called “Blagovest”, there you can find most of what you need.

      With the ability to turn off the fan, it will be more expensive - about 11,800 rubles.

      With connection kitchen hood 5000 RUR + 480 RUR for each meter of air duct with sound insulation.

      REMEMBER! If you have in your kitchen geyser, then you cannot install a mechanical hood! A reverse draft may form in the gas column, and then carbon monoxide will go indoors. For this reason, fatal tragedies occur every year. The standards were written by engineers for a reason; they were written in someone’s blood.

  • To ensure that the premises are comfortable and the air exchange occurs in accordance with the standards, each residential building is equipped with a ventilation system. This also applies to multi-storey buildings, which represent the main segment of urban housing.

    During construction use standard circuits ventilation systems in an apartment building, thanks to which various air circulation modes are implemented.

    In this article we will look at the features traditional schemes, the subtleties of arranging forced ventilation and the nuances of arranging ventilation sewer system.

    Many years of construction practice apartment buildings led to the selection of several of the most effective schemes creating a ventilation system. The choice of one scheme or another depends on many factors: the shape of the building, the number of floors, street air pollution in the area, and noise level.

    Diagrams of a traditional exhaust system

    An exhaust ventilation system with natural impulse is recognized as traditional, that is, when air exchange in rooms is carried out due to the difference in temperature and pressure.

    This means that exhaust air is discharged through ventilation shafts and ducts to the outside (to the roof), and fresh air enters through windows, doors or special ones.

    One of the options for installing ventilation shafts in a multi-storey building

    The option of laying separate shafts for each apartment is not currently being considered, since it was feasible in the era of low-rise construction.

    It is clear that for high-rise buildings from 9 floors and above it is physically impossible to equip many parallel channels.

    Therefore, two recognized rational schemes are used in construction:

    • All shafts lead to the attic and there they are united by a horizontal channel. Contaminated air is removed from the channel through a single exit, located in the most convenient location.
    • Individual apartments are connected to a common riser(mine) with parallel satellite channels, thus exhaust air is discharged above the roof through vertical channels.

    The fundamental difference lies in two points: the presence/absence of a horizontal collector in the attic and the presence/absence of common shafts in the risers.

    Unlike natural ventilation, incentive ventilation is energy-dependent. In addition, it consists of a set of complex devices that are controlled from a single remote control.

    SHUV is installed next to supply equipment, in the basement, and only qualified personnel have access to it service staff.

    We can say that in residential high-rise buildings all three types of ventilation are present, with natural being the most common, and installation of forced or combined system limited for now.

    Organization of air circulation in the apartment

    Let's consider how air circulates in a single apartment without installing additional air exchange devices.

    As mentioned above, fresh air enters through all sorts of window cracks and gaps, as well as through doorways - ajar doors and cracks under them.

    The diagram clearly shows the direction of air movement. It enters through windows or doors of living spaces and moves towards ventilation openings

    Comfortable living in apartments is characterized by a number of factors, including the frequency of air exchange and the volume of regularly changing air.

    There are rules governing admission air flow.

    Ventilation problems negatively affect the well-being of people living in apartments. The lack of fresh air causes unhealthy drowsiness, fatigue, and headaches.

    People with heart disease and respiratory system. They constantly want to keep the vents and windows open, and this leads to a sharp cooling of the premises and, as a result, an increase in the number of colds.

    Increase the effectiveness of natural exhaust system you can use a simple device - a fan installed in the ventilation outlet in the bathroom

    If over kitchen stove A regularly switched-on hood with air exhaust into the ventilation shaft has been installed; this will also contribute to the rapid change of air masses in the kitchen and adjacent rooms.

    If desired, residents can independently organize the air flow. For this purpose, both ordinary ventilation and special mechanical and technical devices, For example, .