Work as an electrician, lineman, overhead line worker, shift. Training for electrician-lineman in the installation of high voltage overhead lines and contact networks. Upon completion of training, you will be issued

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact network. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 12, 2020 - An electrician-lineman is required for the installation of high voltage overhead lines and contact networks. Work on a rotational basis at facilities located in Khanty-Mansi Autonomous Okrug, Yamalo-Nenets Autonomous Okrug. The office is located in Surgut. Requirements: Secondary vocational education Experience...

March 11, 2020 - Responsibilities: - Carrying out work on the construction of overhead power lines - assembling supports, installing wires and cables on VL35KV at the base metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

March 11, 2020 - Responsibilities: - Perform work on the construction of overhead power lines - assembly of supports, installation of wires and cables on VL35KV based on metal supports. Requirements: Must have a certificate of education as a specialist "lineman" and work experience...

February 25, 2020 - In connection with the expansion of the staff, the RSO-Energo Company, specializing in the construction of power lines from 0.4 to 10 kV, is recruiting ELECTRICAL LINE WORKERS, we are also considering formed brigades (work on a permanent basis, NOT ON Shift!!! ). Conditions: Stable...

March 16, 2020 - Responsibilities: Construction of air, cable lines power transmission 0.4-6-10 kV Installation of RP-TP and TP 6-10/0.4 kV Electric installation work Requirements: Specialized education Minimum of 1 year of work experience Conditions: Registration in accordance with the Labor Code Probation Size...

February 21, 2020 - Requirements: Experience in the installation of overhead power lines 0.4-10 kV cable lines, installation of reinforced concrete supports; At least one year of work experience; Conditions: Employment and social package in accordance with the Labor Code of the Russian Federation. Business travel mode. White salary, vacation, sick leave...

March 3, 2020 - Responsibilities: In the field of performing a set of works on the construction of technological connection facilities (overhead and cable lines 0.4-35 kV, TP 6-10/0.4 kV, outdoor switchgear, indoor switchgear 6/10/35 kV): Implementation of the plan technological connection works on the basis of the agreed...

February 19, 2020 - Responsibilities: carrying out work on the contact network and 6/10 kV overhead lines (installation of foundations, anchors, metal and reinforced concrete supports, assembly and installation of rigid crossbars) installation of fittings catenary and overhead lines 6/10 kV (reinforcement of supports, rigid crossbars...

February 25, 2020 - Responsibilities: In the field of performing a set of works on the construction of technological connection facilities (overhead lines and cable lines 0.4-10 kV, TP 6-10/0.4 kV, SP and RP 6-10 kV): Implementation of the work plan for technological connection based on the agreed schedule...

February 13, 2020 - In connection with the opening of a Branch in the city of Kingisepp, the RSO-Energo Company, specializing in the construction of power lines from 0.4 to 10 kV, is recruiting ELECTRICAL LINE WORKERS, we are also considering formed brigades (work on a permanent basis, NOT ON Shift !!!) ...

March 9, 2020 - Complex work on installation and repair of overhead power lines, work at height, moving cargo weighing more than 10 kg. Work in existing electrical installations. Contact person: Krichevskaya Valeria Sergeevna Requirements for candidates: Work experience is required...

March 15, 2020 - Contact person: Alexander Nikitin Requirements for the candidate: Responsibilities: Standard for an electrician-lineman - performing work on the construction of 35 kV overhead power lines (assembling supports, installing wires and cables). Requirements: Education...

March 15, 2020 - Contact person: Alexander Nikitin Our requirements: Responsibilities: Standard for an electrician-lineman - performing work on the construction of 35 kV overhead power lines (assembling supports, installing wires and cables). Requirements: Having an education in...

March 15, 2020 - Contact person: Alexander Nikitin Qualifications: Responsibilities: Standard for an electrician-lineman - performing work on the construction of 35 kV overhead power lines (assembling supports, installing wires and cables). Requirements: Having a special education...

March 15, 2020 - Contact person: Alexander Nikitin Requirements for candidates: Responsibilities: Standard for an electrician-lineman - performing work on the construction of 35 KV overhead power lines (assembling supports, installing wires and cables). Requirements: Education...

Unified Tariff and Qualification Directory of Works and Professions of Workers (UTKS), 2019
Issue No. 3 ETKS
The release was approved by Order of the Ministry of Health and Social Development of the Russian Federation dated 04/06/2007 N 243
(as amended: Orders of the Ministry of Health and Social Development of the Russian Federation dated November 28, 2008 N 679, dated April 30, 2009 N 233)

Electrician-lineman for installation of high voltage overhead lines and contact networks

§ 448. Electrician-lineman for installation of high voltage overhead lines and contact network of the 2nd category

Characteristics of work. Production of small fastening parts that do not require exact dimensions. Manual deepening of grounding conductors. Cleaning of uninstalled steel overhead line (OHL) supports and open substation structures. Painting of attachment parts for attachments and grounding bars. Brush parts wooden supports antiseptic compounds. Removing the casing from the drums and disassembling them. Rolling out wires and cables by hand.

Must know: main brands of linear fittings, insulators, wires and cables; assortment of steel and hardware; rules for handling antiseptic compounds and methods for preserving timber; signaling rules for railway transport; methods of painting wires and grounding bars; methods of deepening grounding conductors manually; name and purpose hand tools and the devices used.

§ 449. Electrician-lineman for installation of high voltage overhead lines and contact network of the 3rd category

Characteristics of work. Installing or removing pin hooks and insulators from uninstalled support posts. Rolling out steel ropes, cables and single-core wires with the installation of drums. Lifting wires onto overhead line supports with voltage up to 20 kV using rods and poles. Cutting and cutting of wires and cables. Laying of grounding slopes, installation of a grounding loop. Depth of grounding conductors power tool. Waterproofing of reinforced concrete structures. Painting of uninstalled steel overhead line supports and open substation structures. Numbering of supports and fastening of tables and posters. Winding wires and cables onto drums with sewing of the drums. Delivery of structures and materials. Moving structures manually.

Must know: types of fasteners, fittings, insulators, wires and cables; design of used electrified and pneumatic hand tools; main types building structures Overhead lines and open substations; device and rules of use used rigging means; grounding and grounding rules.

§ 450. Electrician-lineman for installation of high voltage overhead lines and contact network of the 4th category

Characteristics of work. Assembly of overhead line supports and structures of open substations weighing up to 5 tons. Preparation of parts for wooden supports. Installation and dismantling of overhead line supports and structures of open substations weighing up to 1.5 tons. Rolling out and lifting of wires onto overhead line supports with voltage up to 150 kV and cables - up to 750 kV. Manufacturing of descents, jumpers, loops and half-loops from wires and cables. Installation of arresters. Protection device at crossings. Assembly of insulators and fittings into insulating suspensions for overhead lines with voltages up to 220 kV. Connection of wires and cables with a cross-section of up to 70 mm2. Fastening wires to pin insulators of overhead lines with voltage up to 1 kV. Marking and installation of link and elastic strings on the supporting cable from the ground. Installation of fittings on consoles and flexible cross members. Installation of load limiters with compensated anchorage, locking and feeder brackets on supports. Installation of the middle anchorage on the ground. Suspension support cable from the ground on a support. Inserting insulators into wires and cables on the ground. Installation of interrail connections. Manufacturing and attaching guy ropes to supports. Assembling rigid crossbars. Painting of installed overhead line supports and structures of open substations. Dismantling of wires and cables of overhead lines and contact networks with voltage up to 150 kV. Straightening of single-post supports with voltage up to 20 kV. Installation of cable channels and emergency oil drain. Installation of overhead line entries into buildings. Installation of lamps on supports.

Must know: methods for assembling overhead line supports and open substation structures weighing up to 5 tons; methods for installing overhead line supports and open substation structures weighing up to 1.5 tons; the procedure for arranging and assembling insulators and fittings into insulating pendants for overhead lines with voltages up to 220 kV; methods of connecting wires and cables with a cross-section of up to 70 mm2; methods of lifting and securing wires and cables on supports; the purpose and methods of manufacturing and installing tires, slopes, jumpers and loops from wires and cables; methods for installing load limiters and feeder brackets on supports; methods of installing arresters; types and methods of installing protection for crossings; rules for using mechanized rigging equipment and tools; types of lamps and methods of their installation.

§ 451. Electrician-lineman for installation of high voltage overhead lines and contact network of the 5th category

Characteristics of work. Assembly of overhead line supports and open substation structures weighing over 5 to 10 tons. Installation and dismantling of overhead line supports and open substation structures weighing over 1.5 to 5 tons, except for guyed supports hinged on foundations. Connection of wires and cables with a cross-section of over 70 to 800 mm2. Rolling out stranded wires from non-ferrous metals. Rolling out and lifting wires onto overhead line supports with voltages over 150 to 750 kV and cables over 750 kV. Fastening wires to pin insulators of overhead lines with voltages over 1 kV. Assembly of insulators and fittings into insulating suspensions for overhead lines with voltages over 220 kV. Installation of vibration dampers and spacers on wires and cables. Tensioning and regulation of wires and cables on overhead lines with voltage up to 150 kV. Relaying of wires and cables on overhead line supports with voltage up to 150 kV. Installation of loops. Installing a contact wire limiter. Installation of single and double track consoles. Installation of flexible crossbars. Installation of medium anchors. Installation of electrical connectors and outlets of all types. Rigid anchoring of the supporting cable, supply and reinforcing wires. Lifting the chain suspension under the heel of the console and transferring it to the saddle. Dismantling of wires and cables of overhead lines with voltage over 150 kV. Straightening of complex overhead line supports with voltage up to 20 kV.

Must know: methods for laying out pits and places for immersing piles at pickets of overhead lines and contact networks; methods for assembling overhead line supports and structures of open substations weighing over 5 to 10 tons; methods for installing overhead line supports and open substation structures weighing over 1.5 to 5 tons; the procedure for arranging and assembling insulators and fittings into insulating pendants for overhead lines with voltages over 220 kV; the procedure for phasing wires of contact networks and methods for checking the work performed according to the diagrams; methods of connecting wires and cables with a cross-section of over 70 to 800 mm2; methods of rolling stranded wires from non-ferrous metals; the procedure for rolling out and lifting cables onto the supports of overhead lines with voltages over 750 kV and wires - over 150 to 750 kV; methods for installing distance spacers, vibration dampers on overhead line wires and cables and contact wire limiters; methods for installing loops, flexible crossbars, interfaces, anchor sections; rules for regulating wires and cables on overhead lines with voltages up to 150 kV and catenary circuits at hauls and stations; methods of rigid anchoring of wires on contact network supports; methods of relaying wires and cables on overhead line supports with voltage up to 150 kV; methods of installation and dismantling of arrows and intersections of the contact network.

§ 452. Electrician-lineman for installation of high voltage overhead lines and contact network of the 6th category

Characteristics of work. Assembly of overhead line supports and structures of open substations weighing over 10 to 25 tons. Installation and alignment of reinforced concrete foundations. Installation and dismantling of overhead line supports and structures of open substations weighing over 5 to 20 tons and supports on guy wires, hingedly mounted on foundations, weighing up to 15 tons. Connection of wires with a cross-section of over 800 mm2. Rolling out and lifting wires onto overhead line supports with voltages over 750 kV. Installation of a load compensation unit for tension of contact wires. Compensated anchoring of the contact wire and support cable. Installation of fixing guy wires for chain suspension, couplings of anchor sections, air switches, contact networks in artificial structures, sectional insulators. Installation of supports on mainline railways in operation. Tensioning and regulation of wires and cables on overhead lines with voltages over 150 to 750 kV. Relaying of wires and cables on overhead line supports with voltages over 150 to 750 kV. Installation of wire transpositions on overhead lines with voltage up to 750 kV. Straightening of overhead line supports with voltage over 20 kV. Laying out the route of overhead lines with voltage up to 20 kV.

Must know: methods for assembling overhead line supports and open substation structures weighing over 10 to 25 tons; methods for installing overhead line supports and open substation structures weighing over 5 to 20 tons; rules for installing wire transpositions on overhead lines with voltages up to 750 kV; methods of connecting wires with a cross section of over 800 mm2; rules for installing wires and cables on crossings; methods of compensated anchoring of contact wire and support cable; methods for installing chain suspension braces, anchor sections, air switches, contact networks in artificial structures, sectional insulators; methods of installation and alignment of supports on main and station lines of railways; types of portable radios and rules for handling them; types of theodolites and levels and rules for their use.

§ 453. Electrician-lineman for installation of high voltage overhead lines and contact network of the 7th category

Characteristics of work. Assembly of overhead line supports and open substation structures weighing over 25 tons. Installation and dismantling of overhead line supports and open substation structures weighing over 20 tons and guyed supports hinged on foundations weighing over 15 tons. Construction of monolithic foundations. Installation of transpositions of overhead power lines with voltages over 750 kV. Installation of wires and cables at crossings over large water barriers. Tensioning, adjusting and relaying wires and cables on overhead lines with voltages over 750 kV. Installation of foundations, supports, wires and cables using helicopters. Restoration of the layout of individual sections of the route, marks of foundations and axes of pits for overhead lines with voltages over 20 kV.

Must know: methods for assembling overhead line supports and open substation structures weighing over 25 tons; methods for installing overhead line supports and structures of open substations weighing over 20 tons and guyed supports hinged on foundations weighing over 15 tons; rules for the construction and alignment of monolithic reinforced concrete foundations; rules for installing wires and cables at crossings of large water barriers; ways to do it installation work during the construction of overhead lines using helicopters; rules for regulating wires and cables on overhead lines with voltages over 750 kV; methods for restoring the layout of individual sections of the overhead line route (production picketing).

Secondary vocational education required.

We always present on our website a large number of latest current vacancies. Use filters to quickly search by parameters.

For successful employment, it is desirable to have a specialized education, as well as possess necessary qualities and work skills. First of all, you need to carefully study the requirements of employers in your chosen specialty, then start writing a resume.

You should not send your resume to all companies at the same time. Choose suitable vacancies based on your qualifications and work experience. We list the most important skills for employers that you need to successfully work as an electrician and line operator in Russia:

Top 7 key skills you need to have to get hired

The following requirements are also quite often found in vacancies: electrical energy, construction and negotiations.

As you prepare for your interview, use this information as a checklist. This will help you not only please the recruiter, but also get the job you want!

Analysis of vacancies in Russia

Based on the results of an analysis of vacancies published on our website, the indicated starting salary, on average, is 71,634. It must be borne in mind that the figures given are statistics. The actual salary during employment can vary greatly depending on many factors:
  • Your previous work experience, education
  • Type of employment, work schedule
  • Company size, industry, brand, etc.

Salary level depending on the applicant’s work experience

Training of an electrician-lineman for the installation of high voltage overhead lines and contact networks is carried out in accordance with Order of the Ministry of Education and Science of the Russian Federation No. 739 dated August 2, 2013 “On approval of the federal state educational standard secondary vocational education secondary vocational education by profession 140443.01 Electrician-lineman for installation of high voltage overhead lines and contact networks", "List of professions of workers, positions of employees for which vocational training is carried out", approved by Order of the Ministry of Education No. 513 of 07/02/2013 " On approval of the List of professions of workers, positions of employees for which vocational training is carried out”, the requirements of the Unified Tariff and Qualification Directory of Work and Professions of Workers, the All-Russian Classifier of Professions of Workers, Positions of Employees and Tariff Grades.

High voltage overhead lines are power lines with voltages over 1000 V, designed for the transmission and distribution of electrical energy through wires located on outdoors and attached using insulators and reinforcement to supports (pillars, masts, etc.). High voltage overhead lines are used to transmit high power energy over long distances.

Overhead lines and contact networks consist of sections that are mechanically separated from each other. If the wires of one section break, the other does not fail. This separation simplifies installation, allowing it to be carried out in separate sections.

The profession of an electrician-line operator for the installation of high-voltage overhead lines and contact networks requires the following knowledge: types of fasteners, fittings, insulators, wires and cables; design of used electrified and pneumatic hand tools; main types of building structures of overhead lines and open substations; device and rules for using the rigging equipment used; grounding and grounding rules; methods for laying out pits and places for immersing piles at pickets of overhead lines and contact networks; methods for assembling overhead line supports and open substation structures; methods for installing overhead line supports and open substation structures; the procedure for arranging and assembling insulators and fittings into insulating suspensions for overhead lines; the procedure for phasing wires of contact networks and methods for checking the work performed according to the diagrams; methods of connecting wires and cables with different sections; methods of rolling stranded wires from non-ferrous metals; the procedure for rolling out and lifting cables onto overhead line supports and wires; methods for installing distance spacers, vibration dampers on overhead line wires and cables and contact wire limiters; methods for installing loops, flexible crossbars, interfaces, anchor sections; rules for regulating wires and cables on overhead lines and catenary circuits at hauls and stations; methods of rigid anchoring of wires on contact network supports; methods of relaying wires and cables on overhead power lines; methods of installation and dismantling of arrows and intersections of the contact network, etc.

To work as an electrician-lineman for the installation of high-voltage overhead lines and contact networks, a specialist must undergo professional training, no more than once a year and at least once every 5 years, take short-term training courses of at least 72 hours in order to acquire new knowledge and skills and increase the category, have a medical record with no contraindications, admission to the electrical safety group of at least group 3 up to 1,000 V. It is important that in order to work as an electrician-lineman installing high-voltage overhead lines and contact networks, persons under 18 years of age not allowed.

Cost of training and terms of study

ANO DPO "Comprehensive Training Center for Personnel Retraining" provides vocational training in the following programs:

Form of study: full-time, part-time, distance learning using Internet technologies.

In the process of mastering the training program, developed in accordance with Order of the Ministry of Education and Science of the Russian Federation No. 739 dated August 2, 2013 “On approval of the federal state educational standard of secondary vocational education for secondary vocational education in the profession 140443.01 Electrician-lineman for the installation of high-voltage overhead lines and contact networks,” “ List of professions of workers, positions of employees for which vocational training is carried out”, approved by Order of the Ministry of Education and Science No. 513 dated 07/02/2013 “On approval of the List of professions of workers, positions of employees for which vocational training is carried out” for mastering the working profession of electrician-lineman for installation High voltage overhead lines and contact networks study the following issues:

  • Basics of Electrical Engineering
  • Electrical materials science
  • Reading blueprints
  • Occupational Safety and Health. Providing first medical care in production
  • Electrical safety. Industrial safety rules
  • Construction of high voltage overhead power lines (OHL)
  • High voltage overhead power lines with insulated wires (VLI)
  • Overhead high voltage power lines, carried out by wires with a protective insulating sheath (VLZ)
  • Installation and repair of overhead lines, overhead lines, overhead lines.
  • Mechanization repair work on VL.
  • Rigging work
  • Tests and measurements of overhead lines, VLI, VLZ.

Upon completion of training, you will be issued

  • Certificate for each employee who has passed the certification;
  • Protocol of the certification commission with a list of employees who have passed the certification.

How to get trained as an electrician-lineman in the installation of high voltage overhead lines and contact networks

After completing vocational training (or at a specialized school or training center), an electrician-lineman for the installation of high-voltage overhead lines and contact networks must annually take short-term training courses in the amount of at least 72 hours, no more than once a year and no less than 1 once every 5 years.

Advantages of working with ANO DPO “Comprehensive Training Center for Personnel Retraining”

  • all training programs are developed by teachers taking into account modern educational and teaching materials using new technologies in teaching;
  • A convenient form has been developed for you electronic library By educational material course;
  • the cost of training to become an electrician-lineman for the installation of high-voltage overhead lines and contact networks is significantly lower than that of other training centers;
  • Training takes place at a time convenient for you and in the form required for your organization.

What does failure to complete advanced training within more than 5 years entail?

In accordance with Part 1 of Article 9.1 of the Code of Administrative Offenses of the Russian Federation 1. violation of industrial safety requirements or conditions for carrying out activities in the field of industrial safety of hazardous production facilities entails the imposition of an administrative fine:

  • for citizens - in the amount of 2,000 to 3,000 rubles;
  • on officials- from 20,000 to 30,000 or disqualification for a period of 6 months to 1 year;
  • on legal entities- from 200,000 to 300,000 or administrative suspension of activities for up to 90 days.

Required documents

This job description has been automatically translated. Please note that automatic translation is not 100% accurate, so there may be minor translation errors in the text.

Instructions for the position " Electrician-lineman for installation of high voltage overhead lines and contact networks of the 3rd category", presented on the website, meets the requirements of the document - "DIRECTORY OF Qualification Characteristics of Workers' Professions. Issue 64. Construction, installation and repair work. (Taking into account the additions approved by: order State Committee on construction and architecture N 25 of 08/08/2002, N 218 of 12/22/2003, N 149 of 08/29/2003, letter of the State Committee for Construction and Architecture N 8/7-1216 of 12/15/2004. , by order of the Ministry of Construction, Architecture and Housing and Communal Services N 9 of 12/02/2005, N 163 of 05/10/2006 N 399 of 12/05/2006, by order of the Ministry of Regional Development, Construction and Housing and Communal Services of Ukraine N 558, 12/28/2010)", which was approved by order of the State Committee for Construction, Architecture and Housing Policy of Ukraine on 10/13/1999 N 249. Agreed by the Ministry of Labor and Social Policy of Ukraine. Entered into force on January 1, 2000.
The document status is "valid".

Preface to the job description

0.1. The document comes into force from the moment of approval.

0.2. Document developer: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

0.3. The document has been approved: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

0.4. Periodic verification of this document is carried out at intervals not exceeding 3 years.

1. General Provisions

1.1. The position “Electrician-lineman for installation of high voltage overhead lines and contact networks of the 3rd category” belongs to the “Workers” category.

1.2. Qualification requirements: complete or basic general secondary education. Vocational and technical education without requirements for work experience or obtaining a profession directly in production, advanced training and work experience as an electrician-lineman installing high-voltage overhead lines and contact networks of the 2nd category for at least 1 year.

1.3. Knows and applies in practice:
- types of fasteners, fittings, insulators, wires and cables;
- structure of simple electric and pneumatic hand tools;
- types of overhead power line supports designed for voltages up to 20 kV;
- main types of foundations for supports and electrical structures of open substations and methods of their installation;
- design and rules for using simple rigging equipment;
- grounding and grounding rules.

1.4. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is appointed to the position and dismissed from the position by order of the organization (enterprise/institution).

1.5. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category reports directly to _ _ _ _ _ _ _ _ _ _ .

1.6. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category supervises the work of _ _ _ _ _ _ _ _ _ _ .

1.7. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category during his absence is replaced by a person appointed in the prescribed manner, who acquires the appropriate rights and is responsible for the proper performance of the duties assigned to him.

2. Characteristics of work, tasks and job responsibilities

2.1. Performs simple work for the construction of overhead power lines, contact networks and open switchgears.

2.2. Knows, understands and applies current regulations relating to his activities.

2.3. Knows and complies with the requirements of regulations on labor protection and environment, complies with the standards, methods and techniques of safe work performance.

3. Rights

3.1. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to take actions to prevent and eliminate cases of any violations or inconsistencies.

3.2. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to receive all social guarantees provided for by law.

3.3. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to demand assistance in the performance of his duties. job responsibilities and exercise of rights.

3.4. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to demand the creation of organizational and technical conditions necessary for the performance of official duties and the provision necessary equipment and inventory.

3.5. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to get acquainted with draft documents relating to his activities.

3.6. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to request and receive documents, materials and information necessary to fulfill his job duties and management orders.

3.7. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to improve his professional qualifications.

3.8. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to report all violations and inconsistencies identified in the course of his activities and make proposals for their elimination.

3.9. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category has the right to familiarize himself with documents defining the rights and responsibilities of the position held, and criteria for assessing the quality of performance of job duties.

4. Responsibility

4.1. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for failure to fulfill or untimely fulfillment of the requirements of this job description obligations and (or) non-use of granted rights.

4.2. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for non-compliance with the rules of internal labor regulations, labor protection, safety precautions, industrial sanitation and fire protection.

4.3. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for the disclosure of information about an organization (enterprise/institution) related to a trade secret.

4.4. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for non-fulfillment or improper fulfillment of internal requirements regulatory documents organization (enterprise/institution) and legal orders of management.

4.5. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for offenses committed in the course of his activities, within the limits established by the current administrative, criminal and civil legislation.

4.6. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for causing material damage to an organization (enterprise/institution) within the limits established by the current administrative, criminal and civil legislation.

4.7. An electrician-lineman for the installation of high-voltage overhead lines and contact networks of the 3rd category is responsible for the unlawful use of the granted official powers, as well as their use for personal purposes.

5. Examples of work

5.1. Reinforcement and equipping of uninstalled supports and structures with pins, hooks and insulators.

5.2. Arranging insulators and linear fittings into insulating suspensions for overhead power lines designed for voltages up to 20 kV.

5.3. Rolling out steel ropes, cables and single-core wires with installation of drums.

5.4. Lifting wires on single-stand supports of overhead power lines, designed for voltages up to 20 kV.

5.5. Installation of grounding and grounding of overhead power lines or contact networks.

5.6. Deepening of grounding conductors with mechanized tools.

5.7. Cutting and cutting of wires and cables.

5.8. Waterproofing of reinforced concrete structures.

5.9. Painting of uninstalled supports and structures of open substations.

5.10. Winding wires and cables onto drums.

5.11. Sewing drums with wound wires and cables.

5.12. Numbering of supports.

5.13. Mounting tables and posters on supports.

5.14. Dismantling of wires and cables of overhead power lines or contact networks designed for voltages up to 1 kV.