Adjusting the Danfoss thermal head. Review of thermostats from Danfoss. This technical design gives two serious advantages at once

Danfoss thermostats for heating radiators and heated floors

5 (100%) votes: 1

A popular brand under which thermostats are produced is Danfoss. Products from this company can be found in almost all stores.

The production technology based on a gas-filled bellows has a patent and is used at the company’s own factories. If you are inclined to buy a Danfoss thermostat, be sure to read the operating instructions.

Find out the price and buy heating equipment and related products you can find here. Write, call and come to one of the stores in your city. Delivery throughout the Russian Federation and CIS countries.

About Danfoss regulators

Why install a thermostat? To maintain a certain indoor air temperature.

The product consists of two parts that complement each other:

  1. Thermostat.
  2. Thermostatic valve.

The Danfoss thermostat valve is connected directly to the radiator, and a thermostat is already mounted on it.

The main thing is a thermostatic element that senses temperature changes and sends a signal to a valve that shuts off the flow of coolant.

Inside the thermal head is a bellows (a corrugated chamber that can change sizes) with gas. At a certain temperature, a gas changes its state (it condenses when cooled). This affects the change in volume and pressure in the chamber, which becomes smaller in size and pulls the spool rod, which in turn opens a gap in the valve for the circulation of the coolant.

When heating occurs, the reverse expansion process starts and the lumen is closed (the standard is 2 V °C exceeding temperature indicator above the indicated one).

When the optimal degree is set on the instrument scale, a certain compression of the tuning spring appears inside, which is associated with a specific gas pressure.

Danfoss produces gas and liquid bellows (more inert, slower to react to temperature fluctuations).

Types and symbols

The abbreviations by which Danfoss heating thermostats are distinguished indicate the type of filler and the purpose of the device:

  • RTS is a liquid bellows;
  • RTD-G – gas powered, suitable for single and two-pipe system without pump;
  • RTD-N is a gas device for one- and two-pipe pump systems.

Danfoss RTR/RTD thermostatic service element with built-in temperature sensor

There are modifications that perform not only their main functions, but also many additional ones. Let's say there is an option to protect against reconfiguration of set indicators. This is convenient when children are constantly in the room. The number of modes and variety of functions in each model is individual.

Popular models of Danfoss thermostats

The company's product range includes many different Danfoss thermostats for batteries. The following are popular:

  1. RTD regulator marked 3640. It is used on 2-pipe heating systems classic type. Equipped with an option that prevents the line from freezing in cool weather. The Danfoss RTD thermostat is used in domestic and industrial environments and has four divisions with marks in the form of Roman numerals.
  2. The designation RAX, as a rule, is for products with liquid that are used for installation on unusual batteries or on heated towel rails. Externally they are very attractive and fit well into the design. The case has only divisions with Roman and Arabic numerals.
  3. The Danfoss RA-299 thermostat operates on gas, has automatic temperature control, and is produced in different colors. Reacts quickly to temperature fluctuations. Only used for installation on classical systems heating.
  4. The Living ECO device has the option of indoor climate control. It can be safely installed in various administrative buildings and residential buildings. The product is distinguished by the presence of an LCD screen, which displays all the necessary data about the thermal fluid. In addition, the case has main buttons for mode settings.
  5. There are also series with many functions; they are suitable for heated towel rails and for different areas of heating equipment. Can be right- or left-handed.

Danfoss Living Connect thermostat

All Danfoss thermostats for heating radiators are supplied with parts that simplify the installation of the device and its future use.

Installation of Danfoss thermal head

The device is mounted precisely on the pipe of the hot water supply circuit. Installation does not involve anything complicated, even in the case of design options, installation follows the same principle. The work is carried out in stages:

  1. Markings are made on the supply pipe to indicate the area that needs to be cut. It is worth considering the dimensions of the valve body. The threaded element is removed, which will fit directly into the pipe.
  2. The heating is turned off and the liquid is drained to prevent a flood in the house.
  3. The excess section of the pipe is cut off according to the marks, and a thread is made with a die on the outer part of the cut.
  4. The joint is treated with a special paste for plumbing work (the manufacturer is not important).
  5. The valve is screwed onto the thread made with a die and tightened tightly with a washer. There is no need to further secure the connection for tightness. The actions performed are sufficient for a reliable connection.
  6. The fuse is removed, the maximum value of “five” is set on the regulator, and a housing with a scale is put on top.
  7. All joints are checked and the heating device is connected to the entire heating system.

If the Danfoss thermostat was connected correctly, then there should be no problems. It is worth checking the operation of the device before opening and closing the valve for the first time.

Setting up the thermostat

All the manufacturer’s devices differ in appearance and technical characteristics, but they are still configured in the same way. To implement it, you need to look at the operating instructions and familiarize yourself with the designation of the modes that are indicated on the device body. Indicators may vary, depending on the model.

Next, to adjust the Danfoss thermostat, set it to the required temperature. This can be done by moving the torque element in a certain direction. If you have installed a device with buttons, all you need to do is press the plus or minus.

It is possible to specify intermediate values ​​when they the best way suitable for creating a specific temperature regime in room. A couple of minutes will pass, and the heating system will have time to adapt to the specified parameters and will heat until the optimal microclimate is achieved. The same applies to refrigeration equipment.

Operation of the regulator in a heated floor system

The Danfoss heated floor thermostat is an important thing for the entire heating system. The device has the responsible function of adjusting the temperature to a comfortable 25 °C.

Flow meters will not help if the pressure is unstable, the air is heated, for example, by the sun's rays, and residents are trying to save on heating while they are not at home.

Experts advise installing a mechanical regulator in small rooms of approximately 10 m².

In large rooms, Danfoss room thermostats with heated floor temperature sensors are used.

The Danfoss thermostatic head deservedly has many positive reviews. This is an easy-to-use item that does not require special attention from the owner after installation and adjustment. As a result, a favorable microclimate is provided in the house, and in some cases, significant savings in money.


Danfoss thermostat is a device that is widely used in various home and industrial heating systems. These samples are different high quality, accuracy and ease of use.

Let's study their features in more detail so that you can also use these advanced mechanisms for your systems.

Description and purpose

Danfoss regulator is a device that is used to regulate the air temperature in a room. Such a device can be used in various heating systems, including those where the heat carrier is water.

The regulator allows you to manually control the operation of such a system, use heat economically, and also turn the entire heating system on and off. The thermostat is used both in home networks and in closed ecosystems such as greenhouses, or in industries. It is also used to operate refrigerators, air conditioners and other systems in which it is important to maintain temperature conditions.

1.1 Design of Danfoss thermostats

Danfoss regulator, regardless of its design. It is a small chamber filled with gas or liquid. This liquid or gas expands when exposed to temperature, pressing on the shut-off valve, which stops the flow of heating fluid into the radiator, causing the system to increase the temperature.

When the room cools, the liquid contracts and a reverse reaction occurs. This operating system is valid for all types of radiators, including products for refrigerators. Almost all products from this manufacturer work according to this principle, including Danfoss RTD and the Danfoss RA line, as well as many others.

2 Model range of Danfoss thermostats

Danfoss has a fairly wide range of thermostats. Currently, its products include the following types of devices:

  • thermostats for the design of regulators of the model range 013G4001-013G4009. Applicable for heated towel rails, as well as various sections of heating networks. Available in versions for right- and left-hand installation;

  • Danfoss RTD 3640 is a type of model for heating systems. Designed for a two-pipe standard system. They have an RTD function to protect against freezing for the winter. This variety is suitable for home and industrial heating systems, but not for refrigerators. It has only 4 divisions, indicated by both Arabic and Roman numerals;

  • RAX models with liquid filler. This series is also intended for heated towel rails and design radiators. The model is applicable to most modern versions of design radiators; it has divisions with both Arabic and Roman numerals;


All presented versions of thermostats are accompanied by a whole series of special accessories that simplify their installation, as well as further use.

Almost all thermostats released in this series are available in three different versions: golden, white, silver. You can choose the type that suits your system, the valve and temperature jack work in almost the same way.

2.1 How to install a Danfoss thermostat?

The Danfoss regulator is mounted directly on the hot supply pipe of your heating system. Installation of any model, including the RTD 3640, RA, is easy. In this case you will have to work like this:

  1. Disconnecting the system from total capacity, cut the pipe of the required size for installing the thermostat. Without this step, the installation will not proceed.
  2. Using special tools, we make a thread on the existing pipe onto which the thermostat will be installed.
  3. We treat the area with plumbing paste, and then attach the RTD 3640, RA or any other valve body to it.
  4. We connect the device itself to the valve, tightening the connection with a washer. Additional sealing is not needed here.
  5. We remove the fuse, set the thermostat to the maximum value of 5, then put a cap with a scale on it. It is important to install it until it clicks for the tightest and highest quality fit.
  6. We check the sealing of the system again, after which we can connect it back to the general supply system. Let the valve open and close once and you will be sure that the equipment is working correctly.

Installation of RTD, RA or other model is complete. Now you can use the device freely.

2.2 How to set up a Danfoss thermostat?

Setting up a device such as the Danfoss RTD regulator, RA is quite simple and accessible to all users. In order to do this, you need to study the temperature scale available at the end of the device (it may differ slightly depending on which version you are using). Then set the temperature you are interested in by simply moving the pointer on the device to the parameter you need.

You can also choose intermediate values ​​if they suit you. In just a few minutes, the valve will adjust to the desired position, and the temperature in the apartment will come to the desired parameter, and you will be able to enjoy the most comfortable microclimate for you. The valve is adjusted in the same way for models for refrigerators.

2.3 Danfoss thermostat and its types (video)

Promarmatura XXI Century LLC offers the widest range of Danfoss products

The range of products includes: | | | | | | |
Danfoss is the world's largest manufacturer of radiator thermostats. Over the years, Danfoss has sold more than 300 million radiator thermostats worldwide, saving millions of liters of fuel every day and preventing the environmental damage caused by tons of carbon dioxide, sulfur compounds and other harmful substances. Radiator thermostats pay for themselves in less than two years, and their standard service life of more than 20 years is an excellent opportunity to save money and energy.

Danfoss radiator thermostats are manufactured with built-in and remote sensors to ensure optimal functioning; plus a wide range of valves and additional equipment make up the widest range of our products.

Thermostatic elements RA 2000 series

Thermostatic elements RA 2000 series - devices automatic regulation temperatures designed to complete radiator thermostats type RA. The radiator thermostat is a direct-acting proportional air temperature controller with a small proportional band, which is currently equipped in heating systems of buildings for various purposes. The RA thermostat consists of two parts:

  • universal thermostatic element RA 2000 series;
  • control valve with pre-set capacity RA-N (for two-pipe heating systems) or RA-G (for one-pipe system). The production program for thermostatic elements of the RA 2000 series includes:
  • RA 2994 and RA 2940 with built-in temperature sensor, heating system frost protection, temperature setting range 5–26 °C, device for fixing and limiting temperature settings. Unlike RA 2990, the RA 2940 thermocouple additionally has a function that ensures 100% shutoff of the thermostat valve;
  • RA 2992 - thermocouples with a remote sensor, protection of the heating system from freezing, a temperature setting range of 5–26 °C, a device for fixing and limiting the temperature setting;
  • RA 2920 - thermoelements with a casing that protects against unauthorized intervention, a built-in sensor, frost protection, a temperature setting range of 5–26 °C, a device for fixing and limiting the temperature setting;
  • RA 2922 - thermoelements with a casing that protects against unauthorized intervention, a remote sensor, frost protection, a temperature setting range of 5–26 °C, a device for fixing and limiting the temperature setting. RA 2992 and RA 2922 are equipped with an ultra-thin capillary tube 2 m long, which is located inside the remote sensor housing, connecting it to the working bellows of the thermostatic element. During installation, the tube is extended to the required length. Series RA 5060/5070 - a range of thermoelements remote control with heating system frost protection, temperature setting range 8–28 °C, device for fixing and limiting temperature settings:
  • RA 5062 - with a capillary tube length of 2 m;
  • RA 5065 - with a capillary tube length of 5 m;
  • RA 5068 - with a capillary tube length of 8 m;
  • RA 5074 - with a capillary tube length of 2 + 2 m.

    All thermostatic elements can be combined with any RA type control valves. The clip connection allows for simple and precise attachment of the thermocouple to the valve. The protective casing of thermoelements RA 2920 and RA 2922 prevents their unauthorized dismantling and reconfiguration by unauthorized persons. Technical characteristics of RA type radiator thermostats comply with European standards EN 215–1 and Russian GOST 30815–2002.

    Technical characteristics of thermostatic elements of the RA 2000 series

    The main device of the thermostatic element is a bellows, which provides proportional control. The thermocouple sensor senses changes in ambient temperature. The bellows and sensor are filled with an easily evaporating liquid and its vapor. The adjusted pressure in the bellows corresponds to its charging temperature. This pressure is balanced by the compression force of the tuning spring. As the air temperature around the sensor increases, some of the liquid evaporates and the vapor pressure in the bellows increases. At the same time, the bellows increases in volume, moving the valve spool towards closing the hole for the flow of coolant into heating device until equilibrium is achieved between the spring force and the vapor pressure. When the air temperature drops, the vapors condense and the pressure in the bellows drops, which leads to a decrease in its volume and movement of the valve spool towards the opening to a position at which equilibrium of the system is again established. The vapor fill will always condense in the coldest part of the sensor, usually furthest from the valve body. Therefore, the radiator thermostat will always respond to changes in room temperature without sensing the temperature of the coolant in the supply pipe. However, when the air around the valve is heated by the heat given off by the piping, the sensor may register more high temperature than indoors. Therefore, to eliminate such influence, it is recommended to install thermostatic elements, usually in a horizontal position. Otherwise, it is necessary to use thermocouples with a remote sensor.

    Selecting the thermostatic element type

    Thermostatic elements with built-in sensor

    When choosing a thermostatic element, you should be guided by the rule: the sensor must always respond to the air temperature in the room.

    Thermostatic elements with integrated sensor must always be positioned horizontally so that ambient air can circulate freely around the sensor. They should not be installed in a vertical position, since the thermal effect on the sensor from the valve body and heating system pipe will lead to improper functioning of the thermostat.

    Thermostatic elements with remote sensor

    Thermostatic elements with a remote sensor should be used if: o the thermoelements are covered with a blind curtain; o the heat flow from the heating system pipelines affects the built-in temperature sensor; o the thermoelement is located in the draft zone; o required vertical installation thermoelement. The remote sensor of the thermostatic element must be installed on a wall free from furniture and curtains or on a baseboard under a heating device if there are no heating system pipelines there. When installing the sensor, the capillary tube should be pulled out to the required length (maximum 2 m) and secured to the wall using the supplied brackets or a special gun.

    RAW series thermostatic elements

    Thermostatic elements of the RAW series are automatic temperature control devices designed to complete radiator thermostats of the RA type. The radiator thermostat is a direct-acting proportional air temperature controller with a small proportional band, which is currently equipped in heating systems of buildings for various purposes. The thermostat type RA consists of two parts: a universal thermostatic element of the RAW series and a control valve with pre-set capacity RA-N (for two-pipe heating systems) or RA-G (for a single-pipe system).

    The production program for thermostatic elements of the RAW series includes:

  • RAW 5010 - thermostatic element with built-in temperature sensor;
  • RAW 5012 - thermostatic element with remote temperature sensor;
  • RAW 5110 is a thermostatic element with a built-in sensor and a device for 100% shut-off of the thermostat valve.

    Thermostatic elements of the RAW series are equipped with devices for protecting the system from freezing, fixing and limiting the temperature setting. The RAW 5012 is equipped with an ultra-thin 2 m long capillary tube, which is wound inside the sensor housing and connects the remote sensor to the thermostatic element. During installation, the pipe is pulled to the required length. The clip connection allows for simple and precise attachment of the thermocouple to the valve.

    Technical characteristics of radiator thermostats with RAW series thermoelements comply with European standards EN 215-1 and Russian GOST 30815-2002.

    To prevent unauthorized dismantling, the thermoelement can be fixed to the valve using a special lock (see Accessories).

    Technical characteristics of RAW series thermostatic elements

    The main device of the thermostatic element is a bellows, which provides proportional control. The thermocouple sensor senses changes in ambient temperature. The bellows and sensor are filled with a special heat-sensitive liquid. The adjusted pressure in the bellows corresponds to its charging temperature. This pressure is balanced by the compression force of the tuning spring. As the air temperature around the sensor increases, the liquid expands and the pressure in the bellows increases. At the same time, the bellows increases in volume, moving the valve spool towards closing the hole for the flow of coolant into the heating device until an equilibrium is achieved between the spring force and the liquid pressure. As the air temperature drops, the liquid begins to compress and the pressure in the bellows drops, which leads to a decrease in its volume and movement of the valve spool towards the opening to a position at which equilibrium of the system is again established. To eliminate the influence warm air It is recommended to install thermostatic elements from the heating pipe of the heating device, usually in a horizontal position. Otherwise, it is necessary to use thermocouples with a remote sensor.

    Thermostatic elements of the RAW-K series

    Thermostatic elements of the RAW-K series are automatic temperature controllers with a small proportional band. RAW-K are designed for installation on thermostat valves from Heimeier, Oventrop or MNG, built into the design of steel panel radiators such as Biasi, Delta, DiaNorm, Diatherm, Ferroli, Henrad, Kaimann, Kermi, Korado, Purmo, Radson, Superia, Stelrad, Veha, Zehnder-Completto Fix. The thermostatic element of the RAW-K series has a liquid sensor with a temperature setting range of 8-28 ° C and is equipped with a device for protecting the heating system from freezing.

    The Danfoss company produces 3 modifications of RAW-K series thermoelements:

  • RAW-K 5030 with built-in temperature sensor;
  • RAW-K 5032 with remote temperature sensor;
  • RAW-K 5130 with a built-in sensor and a device for 100% shut-off of the thermostat valve.

    The RAW-K 5032 is equipped with an ultra-thin 2 m long capillary tube, which is wound inside the remote sensor housing, connecting it to the working bellows of the thermostatic element. During installation, the tube is pulled to the required length. Thermostatic elements of the RAW-K series comply with European standards EN 215-1 and Russian GOST 30815-2002.

    Electronic radiator thermostat Living eco

    Electronic radiator thermostat Living eco® is a programmable microprocessor controller for maintaining a given air temperature, mainly in residential buildings served by a water heating system. The thermostat is designed for installation on the valves of radiator thermostats instead of traditional thermostatic elements.

    Living eco® has programs P0, P1 and P2, which allow you to regulate the room temperature at different times of the day.

    The P0 program maintains a constant air temperature throughout the day. Programs P1 and P2, in order to save energy, can reduce the temperature in the room at certain periods of time, which allows you to adapt the operation of the heating system to the lifestyle of the people living in it.

    The Living eco® thermostat is supplied complete with adapters for installation on the valves of Danfoss thermostats, as well as most other manufacturers. Installing and configuring the Living eco® thermostat is easy; there are only three buttons on the panel.

    The Living eco® thermostat is equipped with a function open window, which turns off the supply of coolant to the heating device when the air temperature in the room sharply decreases, which reduces heat loss and thereby increases the efficiency of the heating system.

    Main characteristics of the thermostat:

  • ensuring energy saving;
  • ease of installation;
  • ease of setup;
  • maintaining a comfortable temperature;
  • "open window" function;
  • valve testing function in summer;
  • PID control law, which ensures accurate temperature maintenance;
  • adaptive adjustment of the time to return to operating mode after the temperature drops;
  • the ability to set different temperatures for weekends and weekdays, as well as up to three periods during the day;
  • long service life of one set of batteries (two years);
  • function of limiting limit (min./max.) temperatures;
  • child lock;
  • a special long-term absence regime, during which the premises are not used for a long time;
  • heating system frost protection function;
  • backlit display;
  • autonomous power supply.

    Pre-installed programs

  • A program without an automatic temperature reduction function - maintains a constant, arbitrarily set temperature throughout the day. Energy saving program - reduces the temperature to 17 °C at night (22.30-06.00). The energy saving program can be changed. Extended energy saving program - reduces the temperature to 17 °C at night (22.30-06.00) and at daytime on weekdays (08.00-16.00). It is possible to change the extended energy saving program.

    The "long absence" function allows you to reduce the temperature in the room when it is not in use. The period of absence and temperature are customizable by the consumer.

    The selection of programs and their settings are made in accordance with the instructions supplied with the thermoelement.

    TWA series thermoelectric actuators

    Thermoelectric mini-actuators of the TWA series are designed for on-off control of various control valves in heating and heating and cooling systems of local ventilation units.

    The actuator is equipped with a visual travel indicator that shows whether the valve is in closed or open position.

    TWA actuators, depending on the modification, can be used with valves of the RA, RAV8 and VMT series manufactured by Danfoss, as well as with valves from Heimeier, MNG and Oventrop, which have a thread for mounting the actuator M 30 x 1.5. If the actuator is used with other types of valves, the valve must be checked to ensure compatible geometry and proper closure. The supply voltage of the electric drive is 24 or 230 V. The valves can be normally closed in the absence of voltage (NC) and normally open (NO). In addition, the normally closed actuator with 24 V supply voltage is supplied with a limit switch (NC/S).

    Thermostat valves with pre-setting RA-N and RA-NCX DN = 15 mm (chrome plated)

    Control valves RA-N and RA-NCX are intended for use in two-pipe pump water heating systems.

    RA-N is equipped with a built-in device for pre-setting (installation) its throughput within the following ranges:

  • Kv = 0.04-0.56 m3/h - for valves DN=10 mm;
  • Kv = 0.04-0.73 m3/h - for valves DN=15 mm;
  • Kv = 0.10-1.04 m3/h - for valves DN=20 and 25 mm.

    Valves RA-N and RA-NCX can be combined with all thermostatic elements of the RA, RAW and RAX series, as well as with the TWA-A thermoelectric actuator.

    To identify the RA-N and RA-NCX valves, their protective caps are painted red. The protective cap must not be used to block the flow of coolant through the heating appliance. Therefore, the handle (code no. 013G3300) must be used.

    Valve bodies are made of pure brass, nickel plated (RA-N) or chrome plated (RA-NCX).

    The technical characteristics of the RA-N and RA-NCX valves in combination with thermostatic elements of the RA, RAW and RAX series comply with the European standards EN 215-1 and the Russian GOST 30815-2002, and the connecting thread size complies with the HD 1215 standard (BS 6284 1984). All radiator thermostats manufactured by Danfoss are manufactured in factories certified to ISO 9000 (BS 5750).

    To prevent deposits and corrosion, the valves of the RA-N and RA-NCX thermostats should be used in water heating systems where the coolant meets the requirements of the Rules for the technical operation of power plants and networks Russian Federation. In other cases, you must contact Danfoss. It is not recommended to use compositions containing petroleum products (mineral oils) to lubricate valve parts.

    Adjustment to the calculated value is carried out easily and accurately without the use of special tools. To do this, perform the following operations:

  • remove the protective cap or thermostatic element;
  • raise the tuning ring;
  • turn the scale of the adjustment ring so that the desired value is opposite the setting mark “o” located on the side of the valve outlet (factory setting “N”);
  • release the setting ring.

    Pre-setting can be made in the range from "1" to "7" at intervals of 0.5. In position "N" the valve is fully open. Installation on the dark area of ​​the scale should be avoided.

    When the thermostatic element is installed, the pre-setting is hidden and thus protected from unauthorized changes.

    Thermostat valve with presetting RA-N with press fitting

    The RA-N valve is intended for use in two-pipe pump water heating systems with copper or stainless steel pipelines. Special crimping tools are required to connect the valve connection to the pipeline. The valve body is identical in appearance and technical characteristics to standard RA-N valves DN = 15 mm. RA-N can be used with all types of thermostatic elements from the RA or RAW series, as well as with specially designed thermostatic elements such as RAX and TWA-A thermoelectric actuator.

    The RA-N control valve is equipped with a built-in device for pre-setting (installation) its flow capacity Kv in the range from 0.04 to 0.73 m3/h.

    To identify the valves, the protective cap is painted red. The cap should not be used to block the regulated medium. For these purposes, a special metal handle (code number 013G3300) should be used. The valve body is made of nickel-plated DZR brass and the pressure pin is made of stainless steel. The pin does not require lubrication during the entire life of the valve. The gland seal can be replaced without draining the piping system. RA-N should be used in water heating systems where the coolant meets the requirements of the Rules for the technical operation of power plants and networks of the Russian Federation. In other cases, you must contact Danfoss. It is not recommended to use compositions containing petroleum products (mineral oils) to lubricate valve parts.

    High capacity thermostat valve RA-G

    The thermostatic valve with increased flow rate RA-G is intended for use, as a rule, in single-pipe water heating systems with pump circulation of coolant that meets the requirements of the Rules for the technical operation of power plants and heating networks of the Russian Federation. The valve is not recommended to be used if the coolant contains mineral oil impurities.

    The RA-G is equipped with a seal that can be replaced without draining the heating system. The pressure pin in the stuffing box is made of chrome-plated steel and does not require lubrication throughout the life of the valve. All versions of RA-G valves can be combined with any thermostatic elements of the RA series.

    RA-G valves are supplied with gray (to identify them) protective caps, which should not be used to block the flow of coolant. Therefore, a special metal service locking handle (code no. 013G3300) must be used.

    Set of thermostatic fittings X-traTM for heated towel rails and design radiators.

    The X-tra™ thermostatic kit is specially designed for heated towel rails. It consists of a thermostat valve, a thermostatic element and a shut-off valve with drain function. The innovative self-sealing connection of the valves to the radiator is made using one-half inch threads. The valves and thermoelement are available in white, chrome and steel versions and are suitable for most heated towel rails. This set is the perfect complement to a heated towel rail. The attractive and compact design allows you to install the thermostat under the heated towel rail parallel to the wall, eliminating accidental impacts on it.

    The range includes two types of thermostats with different principles regulation:

    • RAX, which regulates the room temperature;
    • RTX, which detects and regulates the temperature of the water leaving the heated towel rail. Used on heated towel rails and adjustable 5-10°C above room temperature, the RTX thermostat provides a constant temperature for drying towels.
    The thermostats have the same design, with the exception of the setting scale numbers: on RAX - Roman, on RTX - Arabic.

    The valve assembly is a body with a double-sided self-sealing fitting, which has two sealing rings: one to seal the connection between the fitting and the heated towel rail, and the second to seal the connection between the fitting and the valve body. The Allen screw serves to provide a seal between the valve body and the fitting. If the O-rings do not fit into the fittings of the heated towel rail, a traditional sealing material is used.

  • Heating and ventilation costs average 30-50% family budget. And the problem is not in the function itself, but in poor energy consumption. A convenient solution was offered by Danfoss - a thermostat for controlling the temperature in the house and the operation of the heating system. This device can be used in combination with almost all boilers, including heating devices with liquid coolant.

    A thermal head is used at home, in an apartment, production premises, warehouses, closed greenhouses and conservatories, in a word, wherever a relatively constant temperature regime is required. Moreover, this applies not only to heating, but also to air conditioning. Thus, the thermal head interacts equally successfully with air conditioners, refrigeration equipment and other units responsible for temperature.

    Design features

    The main purpose of the Danfoss thermostat is to long-term maintain the user-selected temperature regime. The design of the device includes two main parts:

    • thermostatic element or as it is also called - thermostat;
    • valve.

    The valve is first mounted on the battery and only the thermostat is installed on it. It is the second element that is the main one in the design of the device. It monitors the ambient temperature and then delivers necessary signal valve, which in turn opens or closes the coolant flow.

    In the internal area of ​​the Danfoss thermostat there is a bellows - a corrugated container filled with gas or liquid. When exposed to temperature, the filler begins to change size and press on stop valve. When the coolant flow is blocked in heating units The temperature begins to rise.

    If the room has become very cold, the filler contracts and a reverse reaction occurs - the chamber pulls the spool rod behind it, which in turn opens the gap in the valve element for coolant to flow in.

    The company produces two types of thermostats - gas and liquid. But the second option is considered more inert; it gives a signal to change the temperature regime much slower.

    Types and symbols of devices

    The type of filler and purpose are determined by the following abbreviation:

    • RTS - liquid bellows

    • RTD-G - gas device for one-pipe or two-pipe systems in which there is no pump

    • RTD-N - gas device for single-pipe, two-pipe pumping systems

    In some models, in addition to the main function, there are a number of additional options. For example, a program to protect against interference in the installed settings by random persons. The option will be convenient for installation in public institutions or children's institutions. The number of modes and types of functions vary depending on the selected modification.

    Model range of devices

    The company produces a fairly wide the lineup Danfoss heating temperature controllers.

    The most popular variations are:

    1. Danfoss RDT marking 3640 - the device is intended for use on two-pipe heating systems standard type. It is equipped with an RTD option, which prevents freezing of the main line during the cold season. Used in domestic and industrial conditions. It has four divisions with designations in the form of Roman numerals.
    2. The Danfoss RAX regulator is a liquid type of device that is used for installation on designer-type radiators or heated towel rails. It has attractive external parameters and a minimalist style. On the case there are only divisions with Roman or Arabic numerals.
    3. Living ECO with the function of monitoring the microclimate in the house. This is an improved series that is successfully used in commercial establishments and residential buildings. The peculiarity of the thermostat for a heating radiator is that it has a liquid crystal screen that provides all the necessary information about the coolant. There are also three main mode setting keys on the case.
    4. The Danfoss RA-299 gas appliance with automated temperature control is available in several color solutions. It responds quickly to temperature changes. It is used exclusively for equipping traditional heating systems.
    5. 013 G4 001-013 G4 009 - multifunctional series of devices suitable for both heated towel rails and various areas of the heating device. There are left- and right-handed types.

    Each of the presented options is equipped with parts that simplify the installation of the device and its subsequent use.

    VIDEO: Review of Danfoss thermostatic kits

    Installation of thermal head

    The Danfoss thermostat is installed directly on the “hot” pipe, which supplies coolant to the domestic heating system. Installation work do not have any difficulties, even when it comes to design variations, the installation principle is the same for everyone.

    Must be followed next stages works:

    1. Make a mark on the supply pipe to determine the area that needs to be cut. In this case, take into account the dimensions of the valve body and remove the threaded element that will fit directly into the pipe.
    2. Turn off the heating and drain the water so as not to flood the house while working.
    3. Cut according to the marks unnecessary area pipes and make a thread on the outer part of the cut using a die.
    4. Treat the connecting part with a special plumbing paste from any manufacturer and a foam tool.
    5. Screw the valve element onto the thread that was made with a die, and then tighten it well with a washer. There is no need to additionally seal the joint area; this connection will be sufficient to prevent the pipe from leaking.
    6. Remove the fuse, set the thermostat to the maximum value of “5” and put the housing with the scale on top. The cap is put on all the way, the defining signal is a loud click, it indicates tight contact of the parts.
    7. Check all connections and connect the heating device back to the general heating system.

    Check the operation of the Danfos regulator before opening and closing the valve device for the first time. If the installation was carried out according to the rules, there should be no problems.

    How to adjust the device

    Although all modifications of Danfoss thermostats have differences in external parameters, technical specifications, setting up devices is done using the same method. To implement this, you will need to refer to the operating instructions and study the designations of the modes indicated on the device body. Indicators may differ depending on which model is used.

    Next, set the device to the desired temperature setting. To do this, move the torque element to the required mode. If a device with push-button control was installed, all manipulations are carried out by pressing the “increase” or “decrease” temperature keys.

    You can also choose an intermediate parameter if it is more suitable for creating a specific microclimate in the house. After a few minutes, the heating system will adjust to the selected values ​​and will heat the room until the desired microclimate is achieved. The valve is adjusted in a similar way for refrigeration units.

    VIDEO: How to properly install a thermal head on a radiator

    On this page you can find and download instructions for Automation, regulators, modules, thermostats,... Danfoss in pdf format.

        Control valves RA-N and RA-NCX are designed for use in two-pipe pump water heating systems. 2009 | Language: RU | pdf 1.27 Mb

        The Danfoss PFM 5000 Standard series device is designed to measure pressure drop, flow and temperature, for hydraulic balancing of heating and cooling systems. User manual. Language: RU | pdf 887.60 Kb

        Danfoss gearbox electric drives AME 55 QM series. Technical description. Language: RU | pdf 136.45 Kb

        Danfoss electric actuators AMI 140 series for on-off control. Technical description. Language: RU | pdf 1.10 Mb

        Danfoss gearbox electric drives AMV 110 NL, AMV 120 NL series. Technical description. Language: RU | pdf 122.06 Kb

        Danfoss thermostatic element QT series - return temperature regulator when used with the AB-QM valve. Technical description. Language: RU | pdf 1.29 Mb

        Automated information measuring system Comfort Contour. Danfoss brochure. Language: RU | pdf 4.65 Mb

        Danfoss ECA Connect series controllers. Passport. Language: RU | pdf 361.34 Kb

        Danfoss thermoelectric actuators of the ABNM series (normally closed) with analogue control. Technical description. Language: RU | pdf 327.77 Kb

        Danfoss ABV series thermoelectric actuators. Technical description. Language: RU | pdf 138.87 Kb

        Danfoss gearbox electric drives of the AMB 162/182 series (230 V) for rotary control valves. Installation instructions. Language: RU | pdf 1.34 Mb

        Danfoss electric drives AME 10 series - EI96L11F. User manual. Language: RU, EN, DE, IT, PL, FR, ES | pdf 799.92 Kb

        Danfoss gearbox electric drives series AME 15(ES), AME 16, AME 25, AME 35. Technical description. Language: RU | pdf 605.78 Kb

        Danfoss gearbox electric drives AME 85, AME 86 series. Technical description. Language: RU | pdf 487.78 Kb

        Danfoss gearbox electric drives series AME 130, AME 140, AME 130H, AME 140H. Technical description. Language: RU | pdf 864.29 Kb

        Danfoss gearbox electric drives AMV 435 series. Technical description. Language: RU | pdf 930.12 Kb

        Danfoss gearbox electric drives AMV 438SU series (with return spring). Technical description. Language: RU | pdf 687.15 Kb

        Thermoelectric actuators Danfoss TWA series. Technical description. Language: RU | pdf 285.27 Kb

        Danfoss ECA 32 series built-in I/O expansion modules for ECL Comfort 310/310B controllers. Technical description. Language: RU | pdf 757.87 Kb

        Danfoss temperature controllers of the ECL Comfort 110 series for heating and hot water supply (DHW) systems. Technical description. Language: RU | pdf 767.25 Kb

        Universal temperature controllers Danfoss series ECL Comfort 210 / 210 V and remote control unit ECA 30. Technical description. Language: RU | pdf 1.16 Mb

        Universal temperature controllers Danfoss series ECL Comfort 310 / 310 V and remote control unit ECA 30. Technical description. Language: RU | pdf 1.25 Mb

        Danfoss programming keys A214, A314 series for ECL Comfort 210 / 310 temperature controllers. Operating instructions. Language: RU | pdf 5.56 Mb

        Danfoss electronic application key A217, A317 series for temperature controllers ECL Comfort 210 / 310. Operating instructions. Language: RU | pdf 4.08 Mb

        Danfoss A230 series programming keys for ECL Comfort 210 / 310 temperature controllers. Operating instructions. Language: RU | pdf 2.43 Mb

        Danfoss programming keys A231, A331 series for ECL Comfort 210 / 310 temperature controllers. Operating instructions. Language: RU | pdf 3.16 Mb

        Danfoss A260 series programming keys for ECL Comfort 210 temperature controllers. Operating instructions. Language: RU | pdf 2.02 Mb

        Danfoss A266 series programming keys for ECL Comfort 210 / 310 temperature controllers. Operating instructions. Language: RU | pdf 3.52 Mb

        Danfoss programming keys A275, A375 series for ECL Comfort 210 / 310 temperature controllers. Operating instructions. Language: RU | pdf 6.43 Mb

        Danfoss programming keys A275, A375 series for ECL Comfort 210 / 310 temperature controllers. Installation instructions. Language: RU | pdf 3.05 Mb

        Danfoss A361 series programming keys for ECL Comfort 310 temperature controllers. Operating instructions. Language: RU | pdf 2.92 Mb

        Danfoss A361 series programming keys for ECL Comfort 310 temperature controllers. Installation instructions. Language: RU | pdf 1.34 Mb

        Danfoss A368 series programming keys for ECL Comfort 310 temperature controllers. Operating instructions. Language: RU | pdf 3.08 Mb

        Danfoss A368 series programming keys for ECL Comfort 310 temperature controllers. Installation instructions. Language: RU | pdf 3.64 Mb

        Danfoss A376 series programming keys for ECL Comfort 310 temperature controllers. Operating instructions. Language: RU | pdf 5.06 Mb

        Danfoss A376 series programming keys for ECL Comfort 310 temperature controllers. Installation instructions. Language: RU | pdf 2.31 Mb

        Communication capabilities of Danfoss temperature controllers of the ECL Comfort 210 / 310 series. Operating instructions. Language: RU | pdf 673.15 Kb

        OPC server for Danfoss temperature controllers of the ECL Comfort 310 series. Operating instructions. Language: RU | pdf 999.75 Kb

        USB driver. Connecting ECL Comfort 210 / 310 temperature controllers to a PC. Installation instructions. Language: RU | pdf 223.44 Kb

        New Danfoss ECL Comfort 210 / 310 controllers offer enhanced functionality and maximum efficiency. Brochure. Language: RU | pdf 2.97 Mb

        Danfoss temperature controllers ECL Comfort 210 / 310 series. User manual. Language: RU | pdf 3.85 Mb

        Selection of ECL keys. User manual. Language: RU | pdf 267.81 Kb

        Selection of ECL keys. User manual. Conversion table with codes. Language: RU | pdf 18.62 Kb

        Danfoss FH-WC series patch panel for system control underfloor heating. Technical description. Language: RU, EN, DE, IT, FR | pdf 85.25 Kb

        Danfoss FH-WC series switching panel (230V) for controlling underfloor heating systems. Installation instructions. Language: RU, EN, DE, IT, FR | pdf 2.37 Mb

        Cabinet with connection unit for apartment heating system-1-B1 (ShKSO-1-B1). Technical description. Language: RU | pdf 1.18 Mb

        Cabinet with connection unit for apartment heating system-1-B4, B7 (ShKSO-1-B4, B7). Technical description. Language: RU | pdf 1.24 Mb

        A cabinet with a connection unit for an apartment heating system ShKSO-1 B1 for connecting one apartment. Maintenance instructions. Language: RU | pdf 1.28 Mb

        A cabinet with a connection unit for an apartment heating system ShKSO-1 B1 for connecting one apartment. Installation instructions. Language: RU | pdf 1.04 Mb

        Danfoss residential heat meters of the M-CAL Compact series (modification 447). Passport. Language: RU | pdf 241.12 Kb

        Danfoss residential heat meters of the M-CAL Compact series (modification 447). Brochure. Language: RU | pdf 246.47 Kb

        Residential heat meters Danfoss M-Cal MS series. Passport. Language: RU | pdf 498.30 Kb

        Residential heat meters Danfoss M-Cal MS series. Technical description. Language: RU | pdf 202.01 Kb

        Danfoss residential heat meters of the M-Cal MS series for measuring, processing and presenting current and archived information on the amount of consumed thermal energy, temperature, coolant flow and related data in closed systems water heating for individual consumers (apartment metering). Information booklet. Language: RU | pdf 444.39 Kb

        Residential heat meters Danfoss Sonometer 500 series. Passport. Language: RU | pdf 293.87 Kb

        Ultrasonic apartment heat meters of the Danfoss Sonometer 500 series for measuring, processing and presenting current and archived information on the amount of consumed thermal energy, temperature, coolant flow and other data in closed water heating systems of individual consumers (apartments, cottages, office premises). Information booklet. Language: RU | pdf 394.82 Kb

        Ultrasonic apartment heat meters Danfoss Sonometer 1100 series for measuring, processing and presenting current and archived information on the amount of thermal energy consumed, temperature, coolant flow and other data in closed water heating systems of individual consumers (apartments, cottages, office premises). Information booklet. Language: RU, EN | pdf 242.78 Kb

        Ultrasonic apartment heat meters Danfoss Sonometer 1100 series. Passport. Language: RU, EN | pdf 1.23 Mb

        Remote controller MBus ID = 0x2F for residential heat meters Danfoss Sonometer 1100 series. Operating instructions. Language: RU, EN | pdf 1.70 Mb

        Residential heat meters Danfoss Sonometer 1000 series. Passport. Language: RU, EN | pdf 1.68 Mb

        Ultrasonic flow meter Sono 1500 CT for measuring the flow and volume of various liquids at public utilities and in other industries during technological and accounting operations. Passport. Language: RU | pdf 400.05 Kb

        Heat calculators SPT 943 for measuring and accounting for thermal energy and the amount of coolant in closed and open water heating systems. User manual. Language: RU | pdf 607.48 Kb

        Converters pulse signals Danfoss Hydro Port Pulse series for connecting resource metering devices with pulse output to the M-bus network. Passport. Language: RU | pdf 300.96 Kb

        Danfoss Hydro Port Pulse series pulse signal converters. Technical description. Language: RU | pdf 139.01 Kb

        Danfoss Izar Port Pulse Mini series pulse signal converters. Passport. Language: RU | pdf 252.97 Kb

        Danfoss Izar Port Pulse Mini series pulse signal converters. Technical description. Language: RU | pdf 128.78 Kb

        Danfoss concentrators of the Izar Center series, Izar Center Memory - M-Bus signal converters. Passport. Language: RU | pdf 360.97 Kb

        Danfoss concentrators of the Izar Center series, Izar Center Memory 60, 120, 250 - M-Bus signal converters. Technical description. Language: RU | pdf 277.00 Kb

        Dispatch system individual accounting thermal energy M-bus. Technical information for designers, installers, sales engineers. Language: RU | pdf 727.36 Kb

        Radiator meters - Danfoss distributors of the INDIV-3, INDIV-3R, INDIV-3R2, INDIV-3RD series. Passport. Language: RU | pdf 460.78 Kb

        Radiator heat distributors INDIV-3 for organizing apartment heat metering in residential buildings with vertical wiring heating systems. Information booklet. Language: RU | pdf 486.92 Kb

        Pulse adapter Danfoss INDIV PAD series. Technical description. Language: RU | pdf 253.81 Kb

        INDIV RM radio module kit for personal computer. Technical description. Language: RU | pdf 198.32 Kb

        Network nodes NNV- and NNB-. Installation and operation instructions. Language: RU | pdf 515.57 Kb

        Danfoss individual energy metering system of the INDIV AMR series with remote wireless reading of meter readings. Installation and operation instructions. Language: RU | pdf 647.70 Kb

        Pulse adapter Danfoss INDIV PAD series. Passport. Language: RU | pdf 338.95 Kb

        Danfoss network nodes NNB, NNV series. Passport. Language: RU | pdf 335.04 Kb

        Design of the INDIV AMR system. Information booklet. Language: RU | pdf 5.70 Mb

        Danfoss electronic devices of the INDIV-5, INDIV-5R, INDIV-5R-1 series for thermal energy distribution. Passport. Language: RU | pdf 282.60 Kb

        Installation of Danfoss INDIV-5 (5R) series heat distributor meters on bimetallic radiators. Installation instructions. Language: RU | pdf 1.16 Mb

        Installation of heat distributor meters Danfoss INDIV-5 (5R) series on cast iron sectional radiators. Installation instructions. Language: RU | pdf 908.17 Kb

        Installation of Danfoss heat meters - heat distributors of the INDIV-5, INDIV-5R series on Accord convectors. Installation instructions. Language: RU | pdf 1.01 Mb

        Installation of Danfoss heat distributor meters of the INDIV-5, INDIV-5R series on “Universal” convectors with a welded bracket. Installation instructions. Language: RU | pdf 2.54 Mb

        Installation of Danfoss heat distributor meters of the INDIV-5, INDIV-5R series on Universal convectors with a direct valve. Installation instructions. Language: RU | pdf 3.03 Mb

        Installation of Danfoss heat distributor meters of the INDIV-5, INDIV-5R series on Universal convectors with a U-bend valve. Installation instructions. Language: RU | pdf 3.01 Mb

        Installation of Danfoss INDIV-5 (5R) series heat distributor meters on panel radiators. Installation instructions. Language: RU | pdf 906.56 Kb

        Danfoss radiator distributors of the INDIV series (modifications INDIV-5, INDIV-5R). Information booklet. Language: RU | pdf 1.02 Mb

        Radiator distributors Danfoss INDIV-5, INDIV-5R series. User manual. Language: RU | pdf 122.73 Kb

        Pressure regulators "towards you" Danfoss AVA series (PN 25 / DN 15 - 50). Installation and operation instructions. Language: RU, EN, DE, IT, FR, ES | pdf 1.70 Mb

        Pressure regulators "towards you" Danfoss AVA-AVDS series. Service kits. Installation instructions. Language: RU, EN, DE, IT, FR, ES | pdf 4.76 Mb

        Valves - pressure regulators "towards you" Danfoss AVA series (PN 25). Technical description. Language: RU, EN, DE, IT, FR, ES | pdf 591.49 Kb

        Pressure regulators "afterwards" Danfoss series AVD, AVDS - PN 16, 25 / DN 15 - 50. Installation and operating instructions. Language: RU, EN, DE, IT, FR, ES | pdf 2.62 Mb

        Valves - downstream pressure regulators Danfoss series AVD - for water, AVDS - for steam (PN 25). Technical description. Language: RU, EN, DE, IT, FR, ES | pdf 1.02 Mb

        Valves - pressure regulators "towards you" Danfoss AVDO series. Technical description. Language: RU | pdf 721.33 Kb

        Bypass regulators Danfoss AVDO2 series. Installation and operation instructions. Language: RU | pdf 698.14 Kb

        Pressure regulators "towards you" Danfoss AVDO series. User manual. Language: RU | pdf 827.43 Kb

        Valves - Danfoss differential pressure regulators of the AVP series - with variable settings for the supply and return pipelines; AVP-F - with a fixed setting for the return pipeline (PN16). Technical description. Language: RU, EN | pdf 2.44 Mb

        Danfoss differential pressure regulators AVP, AVP-F series. SP AV accessories. Installation instructions. Language: RU, EN | pdf 739.51 Kb

        Danfoss differential pressure regulators AVP, AVP-F series (SP AV PN 16). Service kits. Installation and operation instructions. Language: RU, EN | pdf 1.42 Mb

        Danfoss differential pressure regulators of the AVP, AVP-F series (PN 16.25 / DN 15 – 50). Installation and operation instructions. Language: RU, EN | pdf 2.11 Mb

        Danfoss differential pressure regulators AVP, AVP-F series (SP AV PN 25). Service kits. Installation and operation instructions. Language: RU, EN | pdf 1.79 Mb

        Danfoss differential pressure regulators AVP, AVP-F series. Accessories. Installation and operation instructions. Language: RU, EN | pdf 748.53 Kb

        Valves - Danfoss differential pressure regulators of the AVP series - with variable settings for the supply and return pipelines; AVP-F - with a fixed setting for the return pipeline (PN 25). Technical description. Language: RU, EN | pdf 1.21 Mb

        Temperature controllers Danfoss AVTB series. Technical description. Language: RU | pdf 776.24 Kb

        Direct-acting temperature controllers Danfoss AVTB series. Installation instructions. Language: RU | pdf 1.63 Mb

        Temperature regulators Danfoss AVTB series, sensor Ø9.5/180 mm. User manual. Language: RU | pdf 80.08 Kb

        Temperature controllers Danfoss AVTB series. Installation instructions. Language: RU | pdf 655.69 Kb

        Temperature regulators RAVК/RAV8 (VMT8, VMA, VMV) of direct action for use in hot water supply systems of small buildings (cottages). Technical description. Language: RU | pdf 1.09 Mb

        Temperature regulators RAVK (25-45 °C). Installation and operation instructions. Language: RU | pdf 1.48 Mb

        Temperature regulators RAVK (25-65 °C). Installation and operation instructions. Language: RU | pdf 1.49 Mb

        Pressure regulators "towards you" Danfoss series AFA / VFG 2 (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 6.02 Mb

        Pressure regulators "towards you" Danfoss AFA / VFG 2 series (21). Technical description. Language: RU, EN, DE, IT, FR | pdf 884.65 Kb

        Downstream pressure regulators Danfoss series AFD / VFG(S) 2 (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 3.74 Mb

        Danfoss downstream pressure regulators series AFD / VFG2 (21), AFD / VFGS2 (for steam). Technical description. Language: RU, EN, DE, IT, FR | pdf 951.72 Kb

        Danfoss differential pressure regulators AFP / VFG series 2 (21) DN 15 - 250. Installation and operating instructions. Language: RU, EN, DE, IT, FR | pdf 3.37 Mb

        Danfoss differential pressure regulators AFP / VFG 2 series. Technical description. Language: RU, EN, DE, IT, FR | pdf 849.64 Kb

        Danfoss differential pressure relief regulators series AFPA / VFG 2 (21) DN 15-250. Installation and operation instructions.

        Danfoss bypass valves AFPA / VFG 2 series. Technical description. Language: RU, EN, DE, IT, FR | pdf 678.71 Kb

        Bypass valves (regulators) Danfoss AVPA series PN 16, 25/DN 15 - 50. Installation and operating instructions. Language: RU, EN, DE, IT, FR | pdf 2.17 Mb

        Bypass valves (regulators) Danfoss AVPA series (PN 16 and PN 25). Technical description. Language: RU, EN, DE, IT, FR | pdf 887.98 Kb

        Differential pressure regulators, flow limiters Danfoss series AFPB(-F) / VFQ2(21) DN 15-125. Installation and operation instructions. Language: RU, EN, DE, FR | pdf 597.42 Kb

        Danfoss differential pressure regulators AFPB-F / VFQ2 series with fixed setting and manual flow limitation. Technical description. Language: RU, EN, DE, FR | pdf 197.75 Kb

        Differential pressure regulators, flow limiters Danfoss series AFPQ (4) / VFQ 2 (21) DN 15 - 250. Installation and operating instructions. Language: RU, EN, DE, FR | pdf 601.56 Kb

        Differential pressure regulators with automatic flow limitation Danfoss series AFPQ / VFQ2 - for installation on the return pipeline, AFPQ 4 / VFQ2 - for installation on the supply pipeline. Technical description. Language: RU, EN, DE, FR | pdf 651.95 Kb

        Flow regulators Danfoss series AFQ / VFQ 2 DN 15 - 250. Installation and operating instructions. Language: RU, EN, DE, FR | pdf 1.23 Mb

        Danfoss flow regulators AFQ / VFQ 2 series. Technical description. Language: RU, EN, DE, FR | pdf 503.85 Kb

        Danfoss drives AFT 06, 26, 17, 27 series for temperature controllers. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 2.72 Mb

        Danfoss thermostatic elements AFT 06, 26, 17, 27 series for temperature controllers. Technical description. Language: RU, EN, DE, IT, FR | pdf 247.06 Kb

        Danfoss differential pressure regulators series AVPB, AVPB-F, AVPBT, AVPBT-F (PN 16.25/DN 15 – 50) with manual flow limitation. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 3.01 Mb

        Danfoss differential pressure regulators of the AVPB, AVPB-F series (PN 25) with manual flow limitation. Technical description. Language: RU, EN, DE, IT, FR | pdf 1.07 Mb

        Danfoss differential pressure regulators of the AVPB, AVPB-F series (PN 16) with manual flow limitation. Technical description. Language: RU, EN, DE, IT, FR | pdf 1.90 Mb

        Danfoss differential pressure regulators of the AVPQ, AVPQ-F, AVPQ 4, AVPQT series (PN 16.25 / DN 15 – 50) with automatic flow limitation. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 3.25 Mb

        Danfoss differential pressure regulators of the AVPQ, AVPQ 4 (PN 25) series with automatic flow limitation. Technical description. Language: RU, EN, DE, IT, FR | pdf 1.41 Mb

        Danfoss differential pressure regulators of the AVPQ, AVPQ-F series (PN 16) with automatic flow limitation. Technical description. Language: RU, EN, DE, IT, FR | pdf 1.97 Mb

        Danfoss flow limiter regulators AVQ series (in combination with a temperature regulator - AVQT) PN 16, 25/DN 15 - 50. Installation and operating instructions. Language: RU, EN, DE, IT, FR | pdf 2.99 Mb

        Danfoss AVQ series flow regulators (PN 25) for supply and return pipelines. Technical description. Language: RU, EN, DE, IT, FR | pdf 496.04 Kb

        Danfoss AVQ series flow regulators (PN 16). Technical description. Language: RU, EN, DE, IT, FR | pdf 482.70 Kb

        Temperature controllers Danfoss AVT series. Installation and operation instructions. Language: RU, EN, DE, IT, FR | pdf 3.05 Mb

        Danfoss temperature regulators of the AVT/VG series - with external thread, AVT/VGF - flanged (PN 25). Technical description. Language: RU, EN, DE, IT, FR | pdf 887.47 Kb

        Temperature controllers Danfoss AVTQ series. Installation and operation instructions. Language: RU, EN | pdf 1.02 Mb

        Danfoss temperature regulators of the AVTQ series (DN 20) with flow correction. Technical description. Language: RU, EN | pdf 485.27 Kb

        Danfoss temperature regulators of the AVTQ series (DN 15) with flow correction. Technical description. Language: RU, EN | pdf 680.90 Kb

        Temperature controllers Danfoss FJV series. Installation and operation instructions. Language: RU, EN | pdf 566.50 Kb

        Return coolant temperature regulators Danfoss FJV series. Technical description. Language: RU, EN | pdf 354.36 Kb

        Return coolant temperature regulators Danfoss FJV series. Passport. Language: RU, EN | pdf 221.26 Kb

        Temperature regulators Danfoss RAVI series. Installation and operation instructions. Language: RU | pdf 1.66 Mb

        Temperature controllers Danfoss RAVI / RAV8 series (VMT8, VMA, VMV). Technical description. Language: RU | pdf 986.78 Kb

        Temperature controllers Danfoss RAVV series. Installation and operation instructions. Language: RU | pdf 1.23 Mb

        Danfoss temperature regulators of the RAVV / RAV8 (VMT8, VMA) series for use in hot water supply systems of small buildings (cottages). Technical description. Language: RU | pdf 1.13 Mb