Selection of vts ventilation system. Ventilation units VTS Clima. Application range of VTS air handling units


We invite you to familiarize yourself with the range of VTS Clima ventilation units. This section of the catalog presents ducted supply, suspended supply and exhaust and floor air handling units. Each type has its own characteristics and advantages, so you will have plenty to choose from.

  • Duct ventilation units of the Ventus N-Type series can only be installed in rectangular ducts ventilation systems. The catalog presents these units in four sizes - according to existing standard series. Each standard size has fan sections, filters, water or electric heating air, air cooling, noise absorbing elements, valves and flexible inserts. The advantage of this series is the case manufacturing technology - Monocoque;
  • Suspended air handling units Ventus VS 10-15 are available in two sizes with air capacity from 400 to 3600 m3/h. Can be used at air temperatures from -40 to +50 degrees Celsius. Designed for indoor use, they are light in weight and low in height, and can be mounted under suspended ceilings. They are equipped with various functional blocks, depending on the client’s requirements;
  • Ventus VS 21-650 floor-mounted air handling units are available in 14 standard sizes and are capable of processing air in the range from 1,200 to 100,000 m3/h. These are dimensional structures intended for installation in production premises, shopping centers and other large facilities. They can operate in a temperature range of -40 to +60 degrees Celsius, and are equipped with all the necessary units to effectively perform the functions of removing air from the room and supplying clean air required temperature and humidity.

Ventilation units VTS Clima - advantages

Ventilation units from this brand have a whole set of significant advantages, which include lightweight, but robust construction(frameless housing), good noise absorption, high degree of energy recovery (up to 85%), the presence of highly efficient PLUG-fans.

A range of standard sizes, ranging from suspended compact units to large ones designed for high consumption air, and wide choose sections that perform all air treatment functions - all this allows you to select the necessary unit, suitable specifically for a given room with the required microclimate parameters.

The Smart Trading company presents all models of ventilation units produced by VTS Clima. Our qualified specialists will provide advice on the selection of installations and help you make the right choice.

Using Newest technologies and innovative engineering solutions, our company has developed unique VTS Clima units. Many years of experience helps us produce units that fully meet the requirements of the modern market. Supply and exhaust and supply systems VTS is a reliable energy-saving equipment, the main functions of which are:

  • movement and filtration of supply and exhaust air;
  • thermodynamic air treatment:
    • hydration,
    • drainage,
    • heating,
    • cooling;
  • energy recovery.

VTS ventilation units: operating features

The units are designed to operate with external air in temperature range from -40 to +60 °C. Air supply and exhaust and air handling units VTS are produced without heat recovery and with rotary and cross-flow types of heat exchangers. Systems with a mixing chamber and/or a glycol circuit operate with outside air not lower than -50 °C, provided that the temperature in the room where they are located does not fall below this level. For VTS ventilation unit with recuperator rotary type The air temperature should not fall below -30 °C.

It is important to note that military-technical installations are not just machines. They include a set of carefully selected and programmed automation applications for control and monitoring that allow you to regulate the operation of ventilation and air conditioning systems. Supply control algorithms used exhaust units VTS Clima were designed to minimize operating costs while maintaining the required parameters of the incoming air, as well as to reduce the likelihood of emergency situations.

Application range of VTS air handling units

  • Buildings of any type, regardless of size: both small restaurants and large shopping centers.
  • Objects for various purposes: commercial, residential, industrial.

A special feature of military-technical equipment is its ability to universal application due to a wide range of functional elements. For example, it is successfully used in both subtropical and arctic climates. Whether it’s an office in Dubai, a factory in Siberia or a shopping center in Budapest – Ventus ventilation units work flawlessly, providing comfort in any climate zone.

Advantages of VTS Klima units

  • Compact sizes:
    • have optimal height (hanging options– from 36 cm, on the foundation – from 53 cm);
    • adapt to the technical and operational features of premises and ventilation ducts.
  • Universal application:
    • VTS Klima air inlets are capable of functioning in any climatic conditions (from -50 to +70 °C);
    • designed for long term operation;
    • parameters confirmed by EUROVENT certificate and laboratory research;
    • can be supplied in sections.
  • Energy saving. Any VTS Clima air handling unit has:
    • PLUG type fan with backward curved blades;
    • direct drive;
    • frequency converter that regulates operating parameters;
    • optimal set of functional elements;
    • simple control algorithms.
  • Automation applications:
    • the VTS exhaust unit can be controlled remotely;
    • automation is open to central management systems (BMS).
  • Frameless design:
    • the Ventus installation has a durable body made of sandwich panels with polyurethane foam insulation;
    • has the highest class of tightness;
    • prevents the emergence of “warm bridges”.
  • A large selection of standard sizes in accordance with the characteristics of any object: customers are provided with 16 standard sizes, as well as the VTS Clima catalog 2015 with a description, technical characteristics and price.

Note that the capabilities of the VTS VS air supply unit have been significantly expanded due to the presence of an adiabatic air humidification section. View more detailed information about VTS Clima units can be found on our official website. Here is a catalog with complete model range VTS installations, the price of which depends on individual technical features.

VENTUS air handling units and central air conditioners are designed to supply rooms with up to 100,000 m3/h of heated air or up to 70,000 m3/h of cooled air. In both cases, heat recovery units can be installed in the air handling unit: recuperative with a cross heat exchanger or a rotating regenerator, allowing up to 85% of the energy to be recovered.

A size range of 16 sizes allows you to select an air handling unit that optimally matches the needs of a particular facility in terms of capital investment and operating costs. The new VENTUS line is optimized for overall dimensions units and made more convenient for placement in a variety of rooms.

The first two standard sizes out of 16 VENTUS (VS10 and VS15) belong to the group of small-sized, “suspended” air handling units. Thanks to the use of VTS modern materials and components, VENTUS air handling units are so compact and lightweight that they allow more powerful machines up to size VS150, which have a capacity of up to 18,000 m3/h, to be mounted in a suspended position.

Suspended air handling units of the first standard size operating in the range of 1000 – 1500 m3/h have a height of only 36 cm. VENTUS air handling units with a capacity of up to 15,000 m3/h can be installed in standard premises height up to 2.6 m Similar, but more powerful machines with an air supply of up to 25,000 m3/h can be placed in rooms with a height of 3.2 m (EU standard).

The new VENTUS air handling units from VTS for ventilation and air conditioning systems include units for outdoor installation on outdoors, as before, but reducing the height of the new equipment made the unit more “flat”, lowered the center of gravity and reduced the “windage” of the hull.

The body panels of the VENTUS air handling unit are made of two galvanized steel sheets, outer sheet covered with an additional anti-corrosion layer. Internal filling The panel is a layer of polyurethane foam. This housing design allows the use of air handling units in various climatic zones(from -40 C to +70 C). Special design locks - labyrinths connecting individual blocks of the body, increases the strength and tightness of the system.

VENTUS air handling units are designed to save energy consumption of the ventilation and air conditioning system, which allows reducing operating costs, in some cases, by 35%. The use of a new fan group with a frequency converter and a frameless fan of a new, improved design in VENTUS air supply units also led to a reduction in power consumption. Increased efficiency of these fans, reduced acoustic noise - all this characterizes the new air handling units VENTUS.

System automatic control, regulation and control developed by VTS for air handling units VENTUS has a freely programmable controller from SIEMENS, specially designed for ventilation and air conditioning systems.
The automation kit has a connector for connecting an external small-sized control panel. External remote control remote control The automation system allows you to easily and quickly read and set the required operating parameters of the VENTUS unit.

In addition, the operating parameters of the unit can be set and controlled using personal computer with standard RS-232 port. It is possible to integrate the automation kit with a building management system (BMS), based on the most common LON standard. VTS air handling units have a certificate of conformity with Rostest, Hygienic Certificate, Eurovent, ISO 9001-14001, CE, TUV. The VTS company gives a 3-year warranty for VENTUS air handling units.

Attention! To receive a CP, you must indicate in your order:

1. Name/purpose of the object.

2. Facility address.

3. Name of the company listed in project documentation(who compiled the project).

If there is no information about the object, please indicate:

  • Performance
  • Total pressure
  • Availability of cooler/heater
  • Cooler/heater type (freon/water, electricity)
  • Inlet and outlet temperatures
  • With or without heat recovery? Recuperator type?
  • Filter type

Or fill out the questionnaire: