S2000M monitoring and control panel with two-line LCD indicator. Installation and principle of operation of the S2000M monitoring and control console Additional options for the console





Description Car S2000-M

Bolide S2000-M is a security and fire control panel designed for use as part of a security and fire alarm together with control and control devices "Signal-20", "Signal-20P", "S2000-4", "Signal-20" series 02, two-wire line controllers "S2000-KDL", control and control devices for firefighters "S2000" -ASPT", relay units "S2000-SP1", and "S2000-KPB", keyboards "S2000-K" and "S2000-KS", display units "S2000-BI", access control controllers "S2000-2".

It is a development of the remote control, maintaining its functions and at the same time having new capabilities.

Additional features:

  • New housing with a large liquid crystal display that is highly informative (2 lines of 16 characters each). There are functional LED indicators“ALARM”, “FIRE”, “FAULT”, “EMERGENCY”, displaying the state of the object
  • The number of sections and alarm loops that can be included in these sections has increased, which allows the use of this remote control at larger facilities
  • Increased maximum amount user passwords
  • Sections can be combined into groups. This allows for easier group control of arming and disarming. Any section can be included in several groups
  • The ability to assign text names not only to sections and users, but also to groups of sections and alarm loops. The text title can be up to 16 characters long
  • Ability to change the names of messages from alarm loops. For each alarm loop added to the remote control database, you can set 32 ​​custom renaming scenarios. Each scenario allows you to set new text names and display type for any 4 standard messages on the device alarm loop
  • The console is configured using the "Database Administrator" program from the "Orion Pro" workstation or the "pprog.exe" utility version 2.00 and higher

Technical characteristics of the Car S2000-M

  • Unit: 1 piece
  • Dimensions (mm): 140x114x25
  • Weight (kg): 0.30
  • Number of devices connected to the RS-485 output - up to 127
  • Number of sections - up to 511
  • Number of partition groups - up to 128
  • The number of alarm loops that can be combined into sections is up to 2048
  • Number of user passwords up to 2047
  • Number of automatically controlled relay outputs up to 256
  • Quantity " entrance zones" - up to 32
  • Ring event buffer capacity - up to 1023 messages
  • RS-485 interface line length up to 3000 m
  • The length of the RS-232 interface line for communication with the printer is up to 20 m
  • Power supply - from a redundant source direct current(for example, "RIP-12" or "RIP-24"). Supply voltage range is from 10.2 to 28.4 V.
  • Typical current consumption - 70 mA at 12 V supply voltage or 35 mA at 24 V supply voltage
  • Operating temperature range - from 0 to +40 °C
  • Weight - no more than 0.3 kg
  • dimensions- 140x114x25 mm

Purpose:
is designed for information integration of ISO “Orion” devices in order to organize a single control center and collect system messages, combine alarm loops into sections, create cross connections between sections and outputs of different devices, and expand information display capabilities.
Interaction between the S2000M console and ISO Orion devices occurs via the RS-485 interface with information transmitted in the Orion protocol.

Main characteristics:
Provides display of system messages on a character liquid crystal screen and their storage in a non-volatile buffer (archive) with the ability to view. Controls the display of section states on the “S2000-BI”, “S2000-BKI” and “S2000-BI” display blocks. 01. For better perception of messages, it is possible to specify text descriptions of sections, alarm loops, addressable detectors and users.
Allows you to manage sections (arm and disarm) using a PIN code on the remote control itself or on the S2000-K and S2000-KS keyboards, Touch Memory keys or Proximity cards from any device that has an input for connecting a reader , from S2000-BKI units, SMS messages via UO-4S.
Allows you to remotely control the S2000-ASPT and Potok-3N devices using commands from the remote control and from the S2000-PT display units: select automatic or manual control mode for fire extinguishing installations, initiate their launch and cancel the launch. Controls the display of the states of fire extinguishing zones on the “S2000-PT” and the states of the water fire extinguishing installation on the “S2000-BI” version. 01.
Provides differentiation of user access rights to management functions.
Has automatic output control function control panels, starting and relay units for 45 different programs.
Supports control scenarios for outputs, voice announcements, alarm loops and access modes. Output control scenarios allow you to create your own programs for controlling actuators. Scenarios for controlling voice notification allow you to control voice notification devices of the "High-horn" series and can be used for synchronous notification and with the division of an object into zones. Access mode control scripts are designed to automatically open doors along escape routes in case of fire. Loop control scenarios can be used to automatically control alarm loops (for arming or disarming) or operating modes of the S2000-ASPT and Potok-3N devices based on system events.
Supports connection to Orion workstation or Orion Pro workstation to increase functionality and system expansion.
Has the ability to connect a printer with a serial RS-232 interface for documenting events or a PC with software AWS "S2000" for displaying events, states of sections and alarm loops.
Ensures the transmission of notifications by the S2000-IT, UO-4S, UO-Orion and S2000-PP devices. It has the ability to connect the ATS100 radio transmitter of the LARS security radio system or the RS-202TD radio transmitter of the Reef String 202 (“LONTA 202”) security radio system for transmitting notifications over the radio channel.
Configuring the console in the “Pprog.exe” program or in the program module Database Administrator of the Orion Pro automated workplace.

Buy Bolide S2000M from Layta at attractive price. Car S2000M: description, characteristics, customer reviews, photographs and related products..

Security and fire control panel "S2000M" is designed to work as part of address system security and fire alarm system and control of fire fighting equipment. Together with ISO “Orion” devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, engineering systems building. Information interaction between the blocks is carried out via a wired RS-485 communication line. The functions of the device can be expanded by connecting additional units.

Peculiarities

Indication of the “Alarm”, “Fire”, “Start”, “Stop”, “Fault”, “Disabled” modes. Ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound alarm alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire-fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
Automatic control by means of light and sound notification, anti-smoke protection, engineering equipment, outputs for transmitting signals “Alarm”, “Fire”, “Start” and “Fault” using control and starting and signal-starting units, receiving and control units. Automatic start and stop of voice alarm devices of the "Horn" series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
Manual control from the remote control keyboard and display units:
control of security and fire alarm operating modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
manual start and stop of light, sound and voice warning systems, smoke protection, engineering equipment;
control of "S2000-ASPT" devices using "S2000-PT" units: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode for the fire extinguishing installation, alarm reset;
control of Potok-3N devices using Potok-BKI units: manual start and stop of the fire extinguishing installation, selection of automatic or manual installation control mode
Possibility of connecting to the Orion Pro automated workstation to expand the capabilities of monitoring the status of the protected object and control
Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility of connecting the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") radio security system or TRX-150 for transmitting notifications via radio channel
Event log with the ability to view it on the remote control screen and print it on a printer with a serial RS-232 interface
Configuring the remote control in the program "Pprog.exe"

It is a development of the "S2000" remote control, maintaining its functions and at the same time having new capabilities. The device is intended for use as part of a security and fire alarm system together with control and control devices "Signal-20", "Signal-20P", "S2000-4", "Signal-20" series 02, two-wire line controllers "S2000-KDL" ", fire-fighting reception and control devices "S2000-ASPT", relay units "S2000-SP1", and "S2000-KPB", keyboards "S2000-K" and "S2000-KS", display units "S2000-BI" , access control controllers "S2000-2".

Additional features:

  • New housing with a large liquid crystal display that is highly informative (2 lines of 16 characters each). There are functional LED indicators "ALARM", "FIRE", "FAULT", "EMERGENCY", displaying the state of the object;
  • The number of sections and alarm loops that can be included in these sections has increased, which allows the use of this remote control at larger facilities.
  • The maximum number of user passwords has increased;
  • Sections can be combined into groups. This allows for easier group control of arming and disarming. Any section can be included in several groups;
  • The ability to assign text names not only to sections and users, but also to groups of sections and alarm loops. The text title can be up to 16 characters long;
  • Ability to change the names of messages from alarm loops. For each alarm loop added to the remote control database, you can set 32 ​​custom renaming scenarios. Each scenario allows you to set new text names and display type for any 4 standard messages on the device alarm loop;
  • The console is configured by the "Database Administrator" program from the "Orion Pro" workstation or by the "pprog.exe" utility version 2.00 and higher.

Specifications

  • The number of devices connected to the RS-485 output is up to 127;
  • Number of sections - up to 511;
  • Number of partition groups - up to 128;
  • The number of alarm loops that can be combined into sections is up to 2048;
  • Number of user passwords up to 1023;
  • The number of automatically controlled relay outputs is up to 256;
  • Number of “input zones” - up to 32;
  • Number of users - up to 2047;
  • The volume of the ring event buffer is up to 1023 messages;
  • RS-485 interface line length up to 4000 m;
  • The length of the RS-232 interface line for communication with the printer is up to 20 m;
  • Power supply - from a redundant DC source (for example, "RIP-12" or "RIP-24");
  • Supply voltage range - from 10.2 to 28.4 V;
  • Typical current consumption is 70 mA at a supply voltage of 12 V or 35 mA at a supply voltage of 24 V;
  • Operating temperature range - from 0 to +40 °C;
  • Weight - no more than 0.3 kg;
  • Overall dimensions - 140x114x25 mm.

Monitoring and control panel with two-line LCD indicator, number of sections - 511, loops (zones) - 2048 (S2000M / C2000M remote control)

The fire-security monitoring and control panel “S2000M” (hereinafter referred to as the remote control) is designed to work as part of an addressable fire-security alarm system and control of fire-fighting equipment. Together with ISO “Orion” devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, and building engineering systems. Information interaction between the blocks is carried out via a wired RS485 communication line. The functions of the device can be expanded by connecting additional units.

Key Features:

  • Indication of the “Alarm”, “Fire”, “Start”, “Stop”, “Fault”, “Disabled” modes. Ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire-fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
  • Automatic control of light and sound warning devices, smoke protection, engineering equipment, alarm, fire, start and fault signal transmission outputs using control and start and signal and start units, receiving and control units. Automatic start and stop of voice alarm devices of the "Horn" series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
  • Manual control from the remote control keyboard and display units:
  • control of security and fire alarm operating modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
  • manual start and stop of light, sound and voice warning systems, smoke protection, engineering equipment;
  • control of "S2000-ASPT" devices using "S2000-PT" units: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode for the fire extinguishing installation, alarm reset;
  • control of Potok-3N devices using Potok-BKI units: manual start and stop of the fire extinguishing installation, selection of automatic or manual installation control mode
  • Possibility of connecting to the Orion Pro automated workstation to expand the capabilities of monitoring the status of the protected object and control
  • Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility of connecting the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") radio security system or TRX-150 for transmitting notifications via radio channel
  • Event log with the ability to view it on the remote control screen and print it on a printer with a serial RS-232 interface
  • Configuring the remote control in the program "Pprog.exe"

Specifications:

PARAMETER NAME

PARAMETER VALUE

Number of ISO “Orion” instruments and devices connected to the RS-485 line, no more

RS-485 interface

Length of RS-485 communication line, no more

RS-232 interface

Number of devices connected to the RS-232 output

1
(computer with workstation, printer, radio transmitter ATS100 or TRX-150 (via converter) or radio transmitter RS-202TD)

Length of RS-232 communication line, no more

Number of alarm loops and addressable detectors grouped into sections, no more

Number of automatically controlled relay outputs, no more

Number of sections, no more

Number of partition groups, no more

Number of user passwords, no more

Event log volume

LCD indicator

2 lines x 16 characters, backlit

from a redundant DC source

Supply voltage

10.2 to 28.4 V

Average current consumption in standby mode

at supply voltage 12 V

at supply voltage 24 V

Maximum current consumption in alarm mode

at supply voltage 12 V

at supply voltage 24 V

Operating temperature range

from minus 10 to +55 °C

Shell protection degree

IP30 (when mounted on a wall)

Weight, no more

dimensions

140x114x25 mm

Type of connection to the device

screw terminal block, wire from 0.2 to 1.5 sq. mm

Installation method

wall-mounted

Equipment consultations New question

Ask a specialist a question about the S2000M monitoring and control panel with a two-line LCD indicator

Question from: Evgeniy

Hello, what version of remote control do you provide?

  • Answered by: Boris Kuzmin Hello. 4.12