Boilers Danko, Ross and Dani - Experts' answers to user questions

Question:

There is a Danko boiler with automatic EUROSIT 630. It is impossible to light the burner; when the control handle is released, the igniter goes out and the igniter flame is small. What can be done?

Answer:

Clean the igniter.

Question:

Boiler Danko 24LK. When turned on, there is a hum for 1 minute, if the main igniter closes completely. What is the reason?

Answer:

Dust in the burners, carbon deposits in the exhaust gas passage of the heat exchanger.

Question:

I have a Danko boiler with KARE automation. Periodically (on different time, about once a week) it stops starting automatically, burns on the wick and that’s it. After you start it manually, the unit automatically starts and works normally for some time. What could be the reason for the boiler not starting automatically, please tell me?

I start the boiler manually like this:

I turn the temperature control knob counterclockwise until it stops.

I open the gas tap.

I press the start button of the thermoelectromagnetic valve, and while holding it, I periodically press the piezo igniter button until the igniter starts to burn.

I slowly release the start button and, making sure that the igniter is lit, slowly turn the thermostat knob to the right, the main igniter lights up. I'm exhibiting desired temperature.

At a given temperature (for example, 60 degrees), the automation (Kare) turns off the device, then when the set temperature drops, the automation starts it up again. Periodically (at different times, about once a week) the boiler stops starting automatically (the temperature dropped to 17 degrees, but for some reason the boiler did not turn on?

After you turn it off and start it “manually”, the boiler works normally and maintains the set temperature again for some time. What needs to be checked, cleaned, purged, changed in order for the boiler to work properly???

Answer:

Check the thermostat.

Question:

Danko boiler, Kare automatics. Sometimes the boiler heats the water to boiling and goes out. And it doesn’t want to switch from the wick to the main torch until you release the tube that goes to the temperature regulator a little from the reducer. The wick burns and does not light the main burners, and when it boils, it goes out completely. Tell me what to do?

Answer:

The main burners turn off when the specified temperature is reached. Causes: contamination of the impulse (connecting) tubes between the membrane valve and the thermostat, jamming of the remote sleeve of the thermostat. When the water temperature reaches 50-90 C, the boiler turns off completely (all): adjust the boiling sensor, there is no draft in the chimney.

Question:

As soon as I fully tighten the bushing on the diaphragm valve, the boiler does not ignite, but as soon as I loosen it a little, it works and leaks gas a little. What to do?

Answer:

Unscrew the screw and remove the handle. Unscrew the screws and remove the scale. Unscrew the screws and remove the thermostat cover. Remove the membrane assembly without damaging the membranes. Remove the assembly by the valve mounting screw.

Remove the spacer bushing. External surface Polish the bushings with emery cloth or a flat file No. 1. Insert the bushing into place.

Reassemble in the reverse order so as not to damage the membrane assembly of the thermostat in the following sequence: insert the screws into the thermostat cover and return the bottom of the cover up, put the membrane assembly on the screws, then carefully insert the thermostat housing onto the screws using the threaded holes and tighten the screws. When assembling, do not allow the cover to rotate relative to the body.

Question:

Ross 12-double-circuit boiler. The squeaking sound is heard in the heating circuit (or inside the boiler heat exchanger). Inside the heat exchanger and when it beeps, you can hear it even in the heating system. How to solve a problem?

Answer:

Poor flow may be causing the whistling noise. It happens that the rubber gasket narrows. Another squeaking sound occurs due to water boiling in some place (or, more precisely, at a point) due to a weak flow (the whistling sound is very similar to the whistling of a kettle before boiling). The problem can only be solved by installing a pump.

Question:

Boiler type Ross 26 NTD. Error E4 began to appear, the water stopped heating and random readings appeared on the temperature display. Tell me, please, what are the problems and solutions?

Answer:

The turbine does not work - maybe there is not enough voltage. It is also possible that the traction pressure switch or traction sensor is faulty.

Question:

I have a Ross-16 double-circuit boiler. When starting, the pilot burner lights up after the main burners are turned on, after a while, a click is heard and the boiler goes out. What could it be?

Answer:

The thermocouple loses voltage, which goes to the magnetic valve.

Question:

Boiler Ross AOGV-11, on the street -10, with gas consumption of about 20 m3/day. A private house 80 sq. m. The boiler is on 2, the temperature in the house is approximately 23 degrees. I thought the consumption should be less. Or I'm wrong?

Answer:

Gas consumption can be checked this way: set automatic to maximum, that is, according to gas meter measure the costs per minute, then multiply the costs per minute by 60. We check the technical characteristics of the boiler and see whether we fit in or not. Depending on the costs, we either adjust the pressure on the gas valve or not.

Question:

I have a 16 kW Ross floor-standing boiler. When heating and cooling, a loud knock (clicking) is heard with a frequency of about 3 seconds, inside at the bottom left, all fasteners are tightened. It may be necessary to adjust the main burner, how should this be done, can it be adjusted while the boiler is running?

Answer:

Perhaps the knocking occurs due to thermal expansion of the metal of the heat exchanger. Cracking is the result of scale and deposits that have formed.

Question:

Ross double-circuit boiler 26ntd - E8 pops up. What does it mean, I can’t decipher the error?

Answer:

The DHW sensor does not work.

Question:

Please tell me about the Ross boiler. The automatic equipment is Eurosit 630. The problem is the following: when you turn off the main burner, it does not go out completely, it burns itself slowly. Please tell me, is this normal?

Answer:

Quite normal. The main burner goes out when the set temperature is exceeded. Before this, the bellows covers the burner in order to save money and maintain the set value.

Question:

Boiler AOGV Dani. Soot appears constantly, they cleaned it several times, everything repeats itself and the boiler stops working. What to do?

Answer:

Pull out the burner and rinse under high pressure of water from the flame side - most likely it is clogged with dust inside, and the gas pressure on the burner may also be too high. Well, clean the heat exchanger from soot.

Question:

Boiler Dani AOGV 7.4. The temperature controller automatically raises the temperature. I bet on 50, next time I come - about 80. The interval between observations is about a month. Everything was fine before. The boiler is 5 years old. What could it be?

Answer:

What gas valve (temperature regulator) is on the unit? It raises the temperature itself - do you mean turn the knob? Or does it not maintain the set temperature? If the latter is a gas valve with a thermal cylinder and a capillary, then first you need to check the functionality of this system itself.

This can be done as follows:

Remove the thermal bulb from the boiler sleeve.

Take two jars of water, an electric boiler for a glass, a thermometer with maximum temperature more than 100 C.

Place an electric boiler for a glass, a thermometer and a thermal bulb in one jar of water. By turning on the boiler and heating the thermal cylinder to a certain temperature and then by cooling (for example, by removing it from a jar of heated water and lowering it into a jar of cold water check (repeatedly) how the gas valve will operate.

If it works normally, then you need to check how the contact between the wall of the thermal cylinder and the wall of the glass (where it is inserted) in the boiler is ensured.

You may need to clean the inside of the glass walls and fill in a thermally conductive liquid, for example machine oil, but it is better to apply thermal conductive paste to the thermal bulb, insert it into the glass and wedge it so that the wall of the thermal bulb is pressed tightly against the wall of the glass.

Question:

on the Dani 7.4 boiler the burner with the wick goes out, it feels like the wind is blowing, it can burn for several minutes, or maybe all day, and then goes out. Please tell me what's the matter?

Answer:

Check the injector for pilot burner. If the wick is blown out by the main burner, then there may still be problems with the exhaust gases from the burner - the passage is clogged or there is not enough gas at the entrance to the boiler and there is not enough gas for the wick when the main valve opens.

Question:

What thermal breaker is installed on Dani Comfort 18 boilers?

Answer:

His brand is M9.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

This article is about how to turn on a Dani boiler with different gas valves.

With the arrival of the autumn-winter period, most people are looking for a way to stay warm and warm their home. Most people use a gas boiler for these purposes. After a long period of not using the boiler or when first meeting with a gas boiler, many people forget or do not know how to start the boiler. Many also do not know what to do if the boiler goes out or does not light up at all. But the gas boiler does not light up, most likely due to it being turned on incorrectly. The same thing happened with us. Our apartment has a Dani parapet gas boiler. And I decided to give you small instructions on launching a Dani gas boiler so that she can help you.

Before turning on the Dani gas boiler, it is necessary to ventilate the room for at least 15 minutes.

Subsequence inclusion apparatus (boiler)with gas valveHONEYWELL»

1. Open the door of the device (boiler). Make sure that the control knob is in the position (the device (boiler) is off). Open the tap on the gas pipeline in front of the device (boiler).

2. Turn the control knob all the way (counterclockwise) to the ignition position and press down, hold it pressed for 5-10 s (the holding time that is necessary to displace air from the pilot burner tube), and turn further, without releasing the knob, to the middle position (there should be a click). If the pilot burner lights up, you must hold the control knob pressed for at least 15 seconds and release it smoothly. Then turn the control knob to the position (the device (boiler) is on) to ignite the burner, while the flame on the pilot burner should not go out.

3. The pilot burner may not ignite until gas pressure forces the air out of the pilot tube. If the flame goes out, repeat the operation after at least 1 minute. If for any reason the burner does not light up and the pilot burner goes out, re-ignite it no earlier than after 5 minutes.

4. The temperature of the coolant in the apparatus (boiler) is regulated by turning the temperature control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90° C.

Drawing. Gas valve “HONEYWELL”

Subsequence inclusion apparatus (boiler)with gas valve « EUROSIT»


Drawing. Gas valve "EUROSIT"

1. Open the door of the device (boiler). Make sure that the temperature control and adjustment knob (control knob) is in the position (appliance (boiler) off). Open the tap on the gas pipeline in front of the device.

2. Turn the control knob counterclockwise to the piezo ignition position.

3. Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks. keep the control knob pressed for 5-10 seconds.

4. Release the control knob and check the presence of flame on the ignition (pilot) burner

5. If there is no flame, repeat the steps, increasing the time you press the control knob.

6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90°C.

Subsequence inclusion apparatus (boiler)with gas valve "ZAO Mashzavod"

ATTENTION! Before igniting the apparatus (boiler), check that the main burner tap is closed

1. Open the door of the apparatus (boiler) and, making sure that valve 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler).

2. Press the start button 1 all the way and, while holding it, press the piezo ignition button 2 until it clicks. The pilot burner may not ignite until the air is forced out of the pilot burner tube by gas pressure. In this case, press the piezo ignition button several times without releasing button 1 until the pilot burner is completely ignited.

3. After 30 seconds (counting from the moment the flame appears on the pilot burner), release the start button, while the flame on the pilot burner should not go out. If the flame goes out, repeat the operation, no earlier than after 5 minutes.


Drawing. Gas valve JSC "Mashzavod"

4. Open burner tap 3 by smoothly turning the tap handle 90° counterclockwise (the tap handle should be parallel to gas pipe). The main burner should light up. If for any reason the burner does not light up and the pilot burner goes out, then it is necessary to close the burner valve 3 and repeat the operations again, but not earlier than after 5 minutes.

5. Turn the temperature adjustment knob 4 to set the required heating temperature of the coolant in the apparatus (boiler). Control heating using temperature indicator 1. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position A to E. Position E approximately corresponds to a temperature of 90ºC of the coolant in the capacitive heat exchanger. Mark 5, corresponding to the set temperature position on the temperature adjustment knob, must coincide with mark 6 on the gas valve body.

Thank you, warmth to everyone.

Question: Boiler Ross AOGV-11, on the street -10, while the gas consumption is about 20 m3/day. Private house 80 sq. m. The boiler is on 2, the temperature in the house is approximately 23 degrees. I thought the consumption should be less. Or I'm wrong? Answer: Gas consumption can be checked this way: set the automatic to the maximum, that is, use the gas meter to measure the costs per minute, then multiply the costs per minute by 60. We check with technical characteristics look at the boiler and see if we fit in or not. Depending on the costs, we either adjust the pressure on the gas valve or not. Question: I have a 16 kW Ross floor-standing boiler. When heating and cooling, a loud knock (clicking) is heard with a frequency of about 3 seconds, inside at the bottom left, all fasteners are tightened.

How to light a dani boiler

If the flame goes out, repeat the operation after at least 1 minute. If for any reason the burner does not light up and the pilot burner goes out, re-ignite it no earlier than after 5 minutes.
4. The temperature of the coolant in the apparatus (boiler) is regulated by turning the temperature control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90° C.


Drawing. Gas valve “HONEYWELL” Sequence of turning on the device (boiler) with the gas valve “EUROSIT” Figure. Gas valve "EUROSIT" 1. Open the door of the device (boiler).


Make sure that the temperature control and adjustment knob (control knob) is in the position (appliance (boiler) off). Open the tap on the gas pipeline in front of the device. 2. Turn the control knob counterclockwise to the piezo ignition position.


3.

Heating boilers dani

Info

Open the door of the apparatus (boiler). Make sure that the control knob is in the position (the device (boiler) is off). Open the tap on the gas pipeline in front of the device (boiler).


2. Turn the control knob all the way (counterclockwise) to the ignition position and press down, hold it pressed for 5-10 s (the holding time that is necessary to displace air from the pilot burner tube), and turn further, without releasing the knob, to the middle position (there should be a click). If the pilot burner lights up, you must hold the control knob pressed for at least 15 seconds and release it smoothly. Then turn the control knob to the position (the device (boiler) is on) to ignite the burner, while the flame on the pilot burner should not go out. 3. The pilot burner may not ignite until gas pressure forces the air out of the pilot tube.

Adjusting the automation in the gas boiler AOGV-18 dani comfort

MTS Group) is one of the world's leading manufacturers of water heating and heating equipment, air conditioners and components for household and industrial use. ARISTON equipment is specially adapted for Russia; during development and testing, many factors that are encountered in Russian operating practice were taken into account: surges in gas pressure and voltage, low temperatures air, water hardness, areas with high seismic activity, etc.
company

Attention

MTS Group is constantly working to improve its products and reserves the right to make necessary technical changes to its products without prior notice. ATTENTION. In addition to the information specified in the manual, it is imperative to observe the relevant standards, rules, instructions and regulations not listed here.

Gas boiler Dani AKGV 12 s

It may be necessary to adjust the main burner, how should this be done, can it be adjusted while the boiler is running? Answer: Perhaps the knocking occurs due to thermal expansion of the metal of the heat exchanger. Cracking is the result of scale and deposits that have formed.

Question: Ross double-circuit boiler 26ntd - E8 pops up. What does it mean, I can’t decipher the error? Answer: The DHW sensor does not work.

Question: Please tell me about the Ross boiler. The automatic equipment is Eurosit 630. The problem is the following: when you turn off the main burner, it does not go out completely, it burns itself slowly.

Please tell me, is this normal? Answer: Quite normal. The main burner goes out when the set temperature is exceeded. Before this, the bellows covers the burner in order to save money and maintain the set value. Question: Boiler AOGV Dani.
This article is about how to turn on a Dani boiler with different gas valves. With the arrival of the autumn-winter period, most people are looking for a way to stay warm and warm their home. Most people use a gas boiler for these purposes. After a long period of not using the boiler or when first meeting with a gas boiler, many people forget or do not know how to start the boiler. Many also do not know what to do if the boiler goes out or does not light up at all. But the gas boiler does not light up, most likely due to it being turned on incorrectly.

The same thing happened with us. Our apartment has a Dani parapet gas boiler. And I decided to give you a little instructions on how to start a Dani gas boiler to help you.

Before turning on the Dani gas boiler, it is necessary to ventilate the room for at least 15 minutes. The sequence of turning on the device (boiler) with the gas valve “HONEYWELL” 1.

Dani gas boiler instruction manual

Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks. keep the control knob pressed for 5-10 seconds. 4. Release the control knob and check the presence of flame on the ignition (pilot) burner 5.

If there is no flame, repeat the steps, increasing the time you press the control knob. 6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90°C. Sequence of turning on the device (boiler) with the gas valve "ZAO Mashzavod" ATTENTION! Before igniting the apparatus (boiler), check that main burner valve 1 is closed. Open the door of the apparatus (boiler) and, making sure that valve 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler). 2.

Soot appears constantly, they cleaned it several times, everything repeats itself and the boiler stops working. What to do? Answer: Pull out the burner and rinse it under high pressure of water from the flame side - most likely it is clogged with dust inside, and the gas pressure on the burner may also be too high.

Well, clean the heat exchanger from soot. Question: Dani boiler AOGV 7.4. The temperature controller automatically raises the temperature. I bet on 50, next time I come - about 80. The interval between observations is about a month. Everything was fine before. The boiler is 5 years old. What could it be? Answer: Which gas valve (temperature regulator) is on the unit? It raises the temperature on its own - do you mean turn the knob? Or does it not maintain the set temperature? If the latter is a gas valve with a thermal cylinder and a capillary, then first you need to check the functionality of this system itself.
Repair, maintenance, technical device, configuration, installation of wall-mounted gas boilers Ariston (Ariston) So, I recently came across a manual for repairing wall-mounted gas boilers Ariston (Ariston). tutorial Genus MTS group. Unfortunately, the book is paperback. Yes, and it was necessary to return it in a couple of days. That’s why I decided to scan this manual for myself. True, the quality of the scanning is let down due to the soft binding, but the manual is quite readable. It contains more than 250 pages. I couldn’t find a similar manual for downloading on the Internet, so I decided to file all the pictures in PDF and put it on deposit so that everyone could download it. I want to say a few more words before I give you a link to the file. Still, the file turned out to be quite large, almost 100 megabytes, so I decided to give detailed description. The book contains logical diagrams of the operation of a gas boiler. principle and device.
БЯ`ИX│7жr?У╝juВО»Д▓%4╩j'ПШ▒╜M╞)Х И┼@И▐пP3QЗmж╙н╡HrпT(ОNvуj~СY╪=VAпTD 4ЦSЄ╗уNХ*╩хП ╜▄╙ vsaGnyai?Ъ@u▒ху╦Gж ┐╠ bK╢мЯlo?√ЎеWПВДЦАХЄ !=ўX1-k╞,gr▓Z╤р F-GYUSHI@╚"(b:Noї╒_^@I╞88Re┘yyo @Kh W7fEl^Ra█T├╛F!T╚х1,ї╗ с'бМЇн╬)ФКе*zq#Д┌ и╥`╔ 1ь1ьмNttИn┤╫╫▐(ЗG┐YИ4√┴Б№╗╨╤░ b!┤╚└┌ Жr╠▄0M()ДЇ)b /ГhМЇ║гФ@┬,t┤kу5├└@JО%┌r=═╚▀ ╞П╥h┘V_Ў╕╤¤a!▀`╤Ъ▌H3TseH ╔l╧6В╨▌╦зъ6б Юj(mG┤╡#4╝Etk╝D╨tEB-,L█syu╣▌w│NhP%─ ╢ЁГb╥ЁoШ8╥ju╪Цш╖gvдНa╥╩чЛf█I ╘┼ jМуЪBш3шх╛▓_|╟ГёЇ╡КW'qEи4°o╞В-d f┐З=Д.╗vus)esh╫ yTBl$J FDR!”bH╗A !bPZеу4wФun[ 1 Шg╞A7YШ! b?) Z│i:У▓ИНЛ_║GЗ√Э╓FЗеm3╖ФАh;bb╖B;ЛChwne╜▒":m┼h│(Д№6.
CONNECTING EXTERNAL CONTROL DEVICES 6.3 MENU AND BOILER SETTING 6.3.1 Setting: LANGUAGE, CURRENT TIME, DATE 6.3.2 Entering the menu 6.3.3 Description of menu 1: TIMER-PROGRAMMER SETTING 6.3.4 Description of menu 2: BOILER SETUP 6.3.5 Description Menu 3: SOLAR HEATING SYSTEM 6.3.6 Description of Menu 4: TEMPERATURE ZONE 1 PARAMETERS 6.3.7 Description of Menu 5: ZONE 2 PARAMETERS 6.3.8 Description of Menu 7: TESTS AND CHECK PROGRAMS 6.3.9 Description of Menu 8: SERVICE TECHNICIAN PARAMETERS 6.4 BOILER INFORMATION MENU (INFO) 6.5 BOILER SAFETY SYSTEMS 6.5.1 Fault codes 6.6 DISPLAYING BOILER OPERATING MODES ON THE LCD DISPLAY 6.7 BOILER CONTROL PANEL 6.8 LCD DISPLAY 7 SERVICE MAINTENANCE 7.1 PROGRAMMING THE TRANSMISSION SERVICE IOD 7.2 PERIODIC CHECKS 8 TECHNICAL CHARACTERISTICS In general, I added some information here , to make it easier to search for a file through search engines.
I set the desired temperature. At a given temperature (for example, 60 degrees), the automation (Kare) turns off the device, then when the set temperature drops, the automation starts it up again. Periodically (at different times, about once a week) the boiler stops starting automatically (the temperature dropped to 17 degrees, but for some reason the boiler did not turn on? After you turn it off and start it “manually”, the boiler works fine, maintains the set temperature again for some time. What needs to be checked, cleaned, purged, changed in order for the boiler to work normally??? Answer: Check the thermostat. Question: Danko boiler, automatic Kare. Sometimes the boiler heats the water to boiling and goes out And it doesn’t want to switch from the wick to the main torch until you release the tube that goes to the temperature regulator a little from the reducer.

Thermostats for heating boilers

Thermostats for heating boilers are important and required part in the unit, without which it will be simply impossible to control the boiler. The boiler thermostat makes it possible to significantly save energy and significantly extend the operating time of the system itself.

Inverter generator for gas boiler

An inverter generator for a gas boiler is simply necessary in order to be sure that power outages will in no way affect the operation of expensive equipment. Such generators are a guarantee uninterrupted operation imported boilers, in which ultra-precise...

Batteries for UPS for heating boilers

Every boiler must have a source uninterruptible power supply, which represents special device(current converter), which converts 12 W from the battery to 220 W. This is the voltage at which all boilers operate. To have an idea of ​​why a UPS is needed, you need to know...

Automation for heating gas boilers AOGV

Automation for gas heating boilers ensures stable and safe work equipment. These systems significantly simplify the use of heating equipment, increase its operating efficiency and allow for the rational use of energy resources. Automation for gas boilers...

It may be necessary to adjust the main burner, how should this be done, can it be adjusted while the boiler is running? Answer: Perhaps the knocking occurs due to thermal expansion of the metal of the heat exchanger. Cracking is the result of scale and deposits that have formed. Question: Ross double-circuit boiler 26ntd - E8 pops up. What does it mean, I can’t decipher the error? Answer: The DHW sensor does not work. Question: Please tell me about the Ross boiler. The automatic equipment is Eurosit 630. The problem is the following: when you turn off the main burner, it does not go out completely, it burns itself slowly. Please tell me, is this normal? Answer: Quite normal. The main burner goes out when the set temperature is exceeded. Before this, the bellows covers the burner in order to save money and maintain the set value. Question: Boiler AOGV Dani.

How to light a dani boiler

This can be done as follows: - Remove the thermal cylinder from the boiler sleeve.


Attention

Take two jars of water, an electric boiler for a glass, and a thermometer with a maximum temperature of more than 100 C.


Place an electric boiler for a glass, a thermometer and a thermal bulb in one jar of water.
By turning on the boiler and heating the thermal cylinder to a certain temperature and then by cooling (for example, by removing it from a jar of heated water and lowering it into a jar of cold water, check (repeatedly) how the gas valve will operate.

If it works normally, then you need to check how the contact between the wall of the thermal cylinder and the wall of the glass (where it is inserted) in the boiler is ensured.

404 not found

The wick burns and does not light the main burners, and when it boils, it goes out completely.


Important

Tell me what to do? Answer: The main burners turn off when the specified temperature is reached.


Causes: contamination of the impulse (connecting) tubes between the membrane valve and the thermostat, jamming of the remote sleeve of the thermostat.

When the water temperature reaches 50-90 C, the boiler turns off completely (all): adjust the boiling sensor, there is no draft in the chimney.

Question: As soon as I fully tighten the bushing on the diaphragm valve, the boiler does not ignite, but as soon as I loosen it a little, it works and leaks gas a little.

What to do? Answer: Unscrew the screw and remove the handle. Unscrew the screws and remove the scale.

Info

Unscrew the screws and remove the thermostat cover. Remove the membrane assembly without damaging the membranes.


Remove the assembly by the valve mounting screw. Remove the spacer bushing.

Adjusting the automation in the gas boiler AOGV-18 dani comfort

Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks.
keep the control knob pressed for 5-10 seconds. 4.

Release the control knob and check the presence of flame on the ignition (pilot) burner 5.

If there is no flame, repeat the steps, increasing the time you press the control knob.

6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7.
Position 7 approximately corresponds to a temperature of 90°C.

Sequence of turning on the device (boiler) with the gas valve "ZAO Mashzavod" ATTENTION! Before igniting the apparatus (boiler), check that the main burner tap 1 is closed.

Open the door of the apparatus (boiler) and, making sure that valve 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler).
2.

Gas boiler Dani AKGV 12 s

Question: Boiler Ross AOGV-11, on the street -10, while the gas consumption is about 20 m3/day.
Private house 80 sq. m. The boiler is on 2, the temperature in the house is approximately 23 degrees.

I thought the consumption should be less. Or I'm wrong? Answer: Gas consumption can be checked this way: set the automatic setting to the maximum, that is, use the gas meter to measure the consumption per minute, then multiply the consumption per minute by 60.

We check the technical characteristics of the boiler and see if we fit in or not.

Depending on the costs, we either adjust the pressure on the gas valve or not.

Question: I have a 16 kW Ross floor-standing boiler. When heating and cooling, a loud knock (clicking) is heard with a frequency of about 3 seconds, inside at the bottom left, all fasteners are tightened.

Dani boiler instruction manual

IiQиr Ж И+╚& H, Жe╛ЭY^Аы(╨н+h,¤ч∙L` L┌╖йУйjO╒╢ЭAR6╖Шф─мъф!9є╠┼АBpзЭПТДЭз┬П╬(┐mгT╞═ИИў ╝K▀e(тT┤╧дХЄJЛ░ППхХ?tX Ж»Z┐ШСкмTO(┬хg%┬╖J°Рne╤е8К&╞Hl┼dпмшХ8ЦSfя╡Sеу╨pX8sBkq4i└ gG·t°цS0с╓ўшД ЁХ-0ус█╨Н╬ ╥;a=/╝└t▒u∙dгв°lme╢╓]ЦЦОш'╢я-▀)нЦVЗд*┤зхХ#(L(!E╔pa2╛┬p /i▀┬+fxМ°уу╣1кJ╖ ∙PEEES*k═╒╤hXagШB╙M)~╣wpПYCtли╜qн╪4╠╕(┘┌╗#СЎ╒hЪ@╥ИD┌╫R▒т;t╔%Сo┼е#ТЭНЇSуK┘Ъ┬ ╨╛ )│оЭ╨ГЎ╚Bj &s─┘KACj[▓wt3ЕЎEQ╘YИ╙&f╦Хь+╥ТЁW╜!gє(╨eеc╫]~9|2ь^iО%3n┘╝ъZ=╜╕д╦Їх3+ў ┘╜_█Ёоц┘r╣f(°4\3v╘ьШ╫TM├╓ыFu▐kagMeYA╨╧dZI╟╦MI,ъРоаш=Ї 6|)[(╡╦7╦╦шЗЇ░Сх:╧3Нж╚ ЇO╣┼BC ┬ 6▀»T╥∙bЛР@╜ВОуО&Ё█евd1┘bIе╠ГЎ╛ Кй╤]+h¤з*─гРжр╡Y($Д*Ц,Л$йЦ,AyUCivНG#ЁИ─ОН░ єИ─Р▀ж^ы─ЪПрПИвSжJ^┼+HVьжhlLkцЎ_tUг╨YXр,╠)/#\gЦ╡чЛ-hЛУ-╛eoWЪ`Z7е8J#Мжb╧,Тєе@╤▀И(*√bPjуИ.БЁ%:р ╗ ╢r°Ў░┬┬╟Ў╖ +6╢^╧V№╒PniEK\m╬E\@Liodj/∙бvЕ+HВб╫ИL│#╤9чц.╢▄▓W╢he√)╦ИТ╜ ¤╝ъ2еЯ)