Connecting the BiLux T26 thermostat (Imit Ta3). Turning on and off

    • Capillary pressure gauge Imit series 962/B (0...6 bar) with capillary 1500 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 96.07 Kb

      Imit Blue series programmable chronothermostats for heating and/or air conditioning systems. User manual. Language: RU | pdf 580.07 Kb

      Imit chronothermostats of the CRX_E series with the possibility of weekly programming. User manual. Language: RU | pdf 1.76 Mb

      Capillary thermomanometer Imit series 941/B (0...120 degrees C; 0...6 bar) with capillaries 1500 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 96.67 Kb

      Capillary thermometer Imit series 902 (0...120 degrees C) with capillary 1500 mm. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 64.42 Kb

      Capillary thermometer Imit series 902 (0...120 degrees C) with a 1000 mm capillary. for continuous pressure measurement of liquids and gases that are neutral to metal. Connection diagram. Specifications. Language: RU | pdf 81.20 Kb

      The combined immersion thermostat Imit series TLSC is used in systems automatic control boiler houses, pumps and other heating installations for setting and automatically maintaining the set coolant temperature and for limiting its maximum value. Connection diagram. Specifications. Language: RU | pdf 85.52 Kb

      Limit thermostat Imit series LS1 6025 (90/110 degrees C) with a 1000 mm capillary. for use in boiler safety systems, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 115.17 Kb

      Limit thermostat Imit series LS1 6035 (100 C) with a capillary of 1500 mm. for use in safety systems for boilers, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 161.33 Kb

      Limit thermostat Imit series LS1 8025 (130 C) with a 1000 mm capillary. for use in safety systems for boilers, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 173.04 Kb

      Limit thermostat Imit series LS1 8035 (63 degrees C) with a capillary of 1500 mm. for use as a safety device in the combustion product removal system of boilers, heating installations and other devices where it is necessary to turn off the gas supply to the burner if the chimney is clogged. Connection diagram. Specifications. Language: RU | pdf 188.15 Kb

      Limit thermostat Imit series LS1 8035 (90/110 degrees C) with a capillary of 1500 mm. for use in safety systems for boilers, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 172.14 Kb

      Limit thermostat Imit series LS1 8135 (90/110 degrees C) with a capillary of 1500 mm. for use as a security device in non-volatile heating boilers, where the coolant temperature should not exceed the set maximum value. Connection diagram. Specifications. Language: RU | pdf 98.22 Kb

      Limit thermostat Imit series LS1 9035 (90/110 degrees C) with a capillary of 1500 mm. for use in safety systems for boilers, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 108.64 Kb

      Limit thermostat Imit series LS1 9045 (110/130 degrees C) with a capillary of 3000 mm. for use in safety systems for boilers, heating installations and other devices where the coolant temperature should not exceed the established maximum value. Connection diagram. Specifications. Language: RU | pdf 117.37 Kb

      Limit thermostat Imit series LS3 (90/110 degrees C) with a capillary of 1000 mm. mainly used as a safety device in non-volatile heating boilers, where the coolant temperature should not exceed the set maximum value. Connection diagram. Specifications. Language: RU | pdf 89.55 Kb

      Imit mechanical immersion thermostat LSC1 series with manual reset is used in heating systems to limit maximum temperature coolant. Connection diagram. Specifications. Language: RU | pdf 79.71 Kb

      Adjustable thermostat Imit series TR2 9325 (0...86 degrees C) with a capillary of 1000 mm. it is applied for automatic regulation temperatures of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 93.22 Kb

      Adjustable thermostat Imit series TR2 0325 (0...90 degrees C) with capillary 1000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 108.17 Kb

      Adjustable thermostat Imit series TR2 9224 (0...210 degrees C) with a capillary of 1000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 89.72 Kb

      Adjustable thermostat Imit series TR2 9322 (0...310 degrees C) with a capillary of 1000 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 97.24 Kb

      Adjustable thermostat Imit series TR2 9325 (0...90 degrees C) with capillary 1000 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 149.96 Kb

      Adjustable thermostat Imit series TR2 9328 (0...40 degrees C) with capillary 1000 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 134.67 Kb

      Adjustable thermostat Imit series TR2 9335 (0...87.5 degrees C) with capillary 1500 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 99.37 Kb

      Adjustable thermostat Imit series TR2 9335 (0...120 degrees C) with capillary 1500 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 96.16 Kb

      Language: RU | pdf 95.67 Kb

      Adjustable thermostat Imit series TR2 9335 (0...87 degrees C) with capillary 1500 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 179.29 Kb

      Adjustable thermostat Imit series TR2 9335 (0...90 degrees C) with capillary 1500 mm. used for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 107.87 Kb

      Adjustable thermostat Imit series TR2 9345 (0...120 degrees C) with capillary 2900 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 84.13 Kb

      Adjustable thermostat Imit series TR2 9345 (0...90 degrees C) with capillary 3000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 121.36 Kb

      Adjustable thermostat Imit series TR2 9345 (16...106 degrees C) with capillary 3000 mm. for automatic temperature control of heating boilers, electric radiators, stoves. Connection diagram. Specifications. Language: RU | pdf 142.17 Kb

      Adjustable thermostat Imit series TRZ 3435 2-stage with capillary 1500 mm. designed for setting and automatically maintaining the set coolant temperature in heating boilers, air heaters and other heating installations where a transition to operation with reduced thermal power is provided. Connection diagram. Specifications. Language: RU | pdf 129.26 Kb

      The adjustable contact thermostat Imit of the BRC series (20...90 degrees C) is used in automatic control systems of heating installations to set and automatically maintain the set coolant temperature. Installation instructions. Passport. Language: RU | pdf 149.02 Kb

      The adjustable contact thermostat Imit of the BRC series (20...90 degrees C) is used in automatic control systems of heating installations to set and automatically maintain the set coolant temperature. Connection diagram. Specifications. Language: RU | pdf 67.71 Kb

      The Imit TC2 series adjustable immersion thermostat is used in automatic control systems for boiler houses, pumps and other installations to set and automatically maintain the set coolant temperature. Connection diagram. Specifications. Language: RU | pdf 81.50 Kb

      Imit series TAZ mechanical room thermostats. Installation and operation instructions. Language: RU | pdf 982.57 Kb

      Imit series TAZ mechanical room thermostats with a signal light and an “on”/”off” switch. Connection diagram. Specifications. Language: RU | pdf 710.14 Kb

Thermostats Italian company IMIT stamps TA3n And TA2n are used to regulate temperature in heating systems to maintain the most comfortable temperature indoors, as well as to save electrical energy used for heating at a time when there are no people in the room. For example, during working hours it is necessary to maintain a temperature of at least +20°C, and at night it is enough to maintain a temperature in the room of +7°C, which allows you to save half of the electrical energy, and therefore saves half of your heating money every day.

Brand thermostats TA3n are practical temperature control devices that are affordable for the consumer and provide high quality regulation.

Currently, TA2n thermostats (temperature regulators) have been discontinued and replaced with an improved model of the TA3n brand.
It inherited ease of use and reliability from the old model. The advanced control knob allows you to limit or fix the set temperature. The TA3n thermostats are available in four modifications to best suit the needs of the consumer: a version with a signal light, an ON/OFF switch or a WINTER/SUMMER switch, as well as without additional functions.

The operation of the TA3n thermostat is based on the expansion of saturated steam in a gas bellows.
Unlike similar devices, TA3n thermostats are highly reliable, because simple mechanical design is not subject to breakdowns.

Technical data of thermostats:

Contact power = 16 (2.5) A/250 V~
Operating range = 5°C - 30°C
Differential =<1К
Insulation class = I
Degree of protection = IP 20
Maximum storage temperature = 50°C
Connection = 2 wire
Output = changeover contacts
Installation = on the wall
Color = white

Article code

Description

Quantity per package, pcs.

Thermostat with function indicator and on/off switch

Thermostat with function indicator

Thermostat without additional functions

Thermostat with function indicator and WINTER/SUMMER switch

Handle lock

to order

Basis for installing a room thermostat on a wall on a 60 mm box. Fits TA3n - black.

to order

INSTALLATION

The thermostat should be installed at a height of about 1.5 m from the floor in an area that reflects the average temperature. Avoid installation in areas with stagnant air, near doors, windows, heat sources, etc.

CONNECTION

Remove the cover by pressing out the fastening “C” (see Fig. in the original passport). Fix the thermostat to the wall with two screws with a maximum diameter of 3.5 mm, using the holes (B-B) on the base of the device.

Note: The thermostat should only be used with a fixed mount.

ELECTRICAL CONNECTIONS

Pull the wires through the hole in the base and connect them to the terminals of the device as shown in the diagram on the inside of the cover.

Attention!

Mechanical room thermostats of the TA2n brand are currently not produced and have been replaced by an improved model of the TA3n brand!

You can download instructions for installation and use of TA3 thermostats

If you have difficulties connecting thermostats, entrust their installation to our engineers.

Main functions.

  • The underfloor heating thermostat with a weekly program is controlled by a single-chip microcontroller.
  • High reliability. Saves energy and creates comfortable indoor conditions.
  • The device works with electric or water heating systems, starting electronic heating or activating the heating system. According to the set temperature, the thermostat automatically turns on and off the controlled object (valve, floor heater, wall heater, electric heaters, etc.).
  • Several time modes of operation: 5+2, 6+1, 7 days, allows you to set different temperatures for weekends and/or weekdays according to six time phases. In this operating mode, the user does not need to manually change the temperature depending on the phase of the day. This will happen automatically.
  • The stylish design of the thermostat will allow you to easily fit it into the design of the room. The smooth surface of the case will make the device easier to clean.
  • All settings are saved after the power is turned off, thanks to the built-in battery.
  • Keypad lock prevents children from accidentally changing device settings.

Technical specifications.

  • Supply voltage:85-250VAC 50/60Hz (24V optional)
  • Internal sensor range: 0-40 o C.
  • Setting range: 5-35 o C (factory: 25 o C)
  • Internal sensor: NTC B=3380 10k@25degrees Celsius
  • Indication step: 0.1 o C. Minimum step: 0.5 o C/step
  • Maximum load power: 16A.
  • External sensor range: 0-99 o C. Setting range: 5-95 o C (factory default: 50 o C)
  • External sensor:NTC B=3380 10k@25degrees Celsius, length 3M

User manual

Turning on and off

By pressing a button you can turn the thermostat on or off.
The display looks like this when the thermostat is turned off.

Children Lock
Press the buttons and hold for about two seconds, after which the buttons will be locked. The lock icon will light up on the screen.
The lock is removed in the same way as it was placed, hold down the buttons for two seconds.

System time
To set the system time: Press and hold the button for 5 seconds to enter the time setting mode. Press and select the parameter you want to change (day of week / hours / minutes), press or to set the desired value of the selected parameter. To return to the previous time setting, press the button.
After setting the required minutes, press to exit the time setting mode.

Temperature Control Modes

The thermostat can operate in three different temperature control modes, enter advanced settings to set.
Built-in sensor(IN): Uses an internal sensor to measure temperature. This mode is suitable for controlling room temperature.
External sensor (OUT): An external sensor is used to measure temperature. This mode is suitable for controlling the floor temperature.
Both sensors (ALL): The thermostat uses both sensors to control temperature. This mode is suitable if you need to control the temperature in the room without overheating the floor

Temperature display in three modes

When the thermostat is in IN mode and ALL mode. The display shows the current air temperature in the room, as indicated by the active AIR icon.
When the thermostat is in OUT mode, FLOOR is lit. The display shows the current floor temperature measured by an external sensor.
When the thermostat is in ALL mode, press and to display the floor temperature or external sensor location and FLOOR will light up. After 5 seconds, the thermostat will automatically switch to the internal sensor readings and the word AIR will appear.

Automatic / manual mode

By pressing the button you can select the thermostat operating mode, automatic or manual.
Manual Mode: The thermostat automatically controls the manually set temperature until it is changed. The set temperature value is displayed below the current temperature reading and can be changed at any time using the and buttons accordingly.
Auto mode: The thermostat automatically controls the temperature at the level set by the program for the current time stage; when the time comes for the next stage, the system will maintain the temperature specified for it. When the thermostat operates in automatic mode, the indicator lights up. Inscriptions Week And Stage light up on the screen alternately with an interval of 5 seconds. When on screen WEEK, the number below indicates the number of the day of the week from 1 to 7. When on the screen Stage, the number below indicates the number of the active time step, from 1 to 6. Under the current temperature, the current time and the temperature set for the active time step are alternately displayed at 5-second intervals.

Setting time steps (thermostat programming)
Stage settings allow you to control the temperature over time automatically. Once you have configured the parameters, you will not need to do anything else; the thermostat will follow the program day after day, creating comfortable conditions for you. The thermostat automatically saves any changes you make and maintains them even after a power outage using a built-in battery.
The thermostat can operate according to three types of schedules (5+2 / 6+1 / 7) with 6 stages. With a cycle of one week.
The beginning of each stage is the time (hours, minutes) and the temperature value that are stored in the program. The end of the current stage is the beginning of the next one.
Press and hold for 5 seconds, you will enter the time stage setting interface. Numbers flashing below the inscription Week indicate which type of schedule is selected (5+2 or 6+1 or 7, by default the 5+2 mode is selected, so the numbers from 1 to 5 are blinking). To select the parameter (Stage start time: hours, minutes and temperature for this stage) that you want to change, use the button. Use or to change the value of the selected option.
Example: a schedule of type 5+2 (5 working days + two days off) is selected. The procedure for setting the period is:
Press and hold for 5 seconds, under the inscription Week, numbers from 1 to 5 will flash as in the figure on the right, set the parameters of the stages for working days P1: set hours>minutes>temperature-> P2: set hours>minutes>temperature -> P3: set hours>minutes>temperature ->...- > P6: set hours>minutes>temperature. Under the inscription Week The numbers 6 and 7 will flash.
let's set the parameters of the stages for weekends P1: set hours>minutes>temperature -> P2: set hours>minutes>temperature -> P3: set hours>minutes>temperature ->...-> P6: set hours>minutes>temperature. After setup last stage The thermostat will switch to automatic mode and begin executing the set program. Moving through the settings of time stages is carried out using the and forward and backward buttons, respectively. Setting the parameter value using the or button.
By default, the manufacturer has entered the following values ​​for time stages:

System settings
Warning: System settings are used to configure very important thermostat parameters. Only change factory settings if you understand what you are doing.

Entering system settings: Turn off the thermostat, and then press the power button again and immediately, no longer than a second, then press the button, the screen will appear instead of the usual numbers, which indicates a successful login from the system settings. If the normal image appears after turning on, please repeat the login operation from the beginning.
Use the button to switch between options. To set the required value of the selected parameter, use the or button. To exit system settings Scroll all the options to the end.

OFF

Image Description Setting range Default value
Temperature calibration -5°C — 5°C -2.5°C
Used to fine-tune temperature measurement. Enter the difference between the thermostat and the reference temperature meter readings
Select a schedule 5+2/6+1/7
The ratio of working hours and weekends is established. You can set the option of working days from Monday to Friday, from Monday to Saturday or all working/non-working days
Anti frostbite ON:Enabled/OFF:Disabled OFF
Prevents the room temperature from falling below 0°C by turning on the heating when the temperature drops below 5°C.
Selecting Temperature Control Mode IN:Internal OUT:External ALL:Both IN
IN: Internal sensor, room temperature OUT: External sensor, floor temperature ALL: Both sensors, room temperature control with floor temperature limitation
External sensor temperature limitation 40-80°C
Operates in ALL temperature control mode, limiting floor temperature
Internal sensor hysteresis 0.5-4°C 1°C
The parameter value indicates how many degrees the thermostat will add to the set room temperature before stopping heating
External sensor hyseresis 0.5-5°C 3°C
The parameter value indicates how many degrees the thermostat will add to the set temperature
Screen backlight operating mode
Specifies how the screen backlight will work
Action after trip OFF: remains switched off ON: in the same state as before switching off OFF
Indicates what mode the thermostat will be in when power is restored after an emergency shutdown
Factory reset Factory reset

Possible malfunctions and methods for eliminating them

  1. Fault phenomenon: There is no display Reason & solution:
    1^ Power supply system is having problems or powjer is supplied incorrectly, please check if the inlet wire is normal.
    2^ If the connection is not right, please wired up as )